[?] Violations: A summary of the violations found during the inspection are listed below. |
5-205.15 (B) / SYSTEM MAINTAINED IN GOOD REPAIR (REPAIRED) Core Item The drain lines for the bar's 3-bay sink - sanitizing bay - & the ice bin right next to it are cut off but have fallen down into the drain. These drain lines must be completely up out of the drain, an indirect connection via an air gap. Cut off the lines or permanently affix them up out of the drain, so that the air literally flows between the end of the drain lines & the floor drain. This is to protect any clean dishes & ice, in case the drain backs up. Correct By: 05-Nov-2013 |
5-501.17 / TOILET ROOM RECEPTACLE, COVERED Core Item Repeat Ladies restroom is not provided with a covered waste receptacle. Provide a covered waste receptacle in ladies restroom. Correct By: 05-Sep-2013 |
6-202.16 / EXTERIOR WALLS AND ROOFS, PROTECTIVE BARRIERS Core Item The north/main door is propped open, allowing the entrance of pests - example: flies.. Keep this door closed, or provide a self-closing screen here. Correct By: 05-Aug-2013 |
6-304.11 / MECHANICAL Core Item Repeat The restroom ventilation fans are not working. There must be ventilation exhaust in restrooms. Repeair these ventilation fans. Correct By: 05-Aug-2013 |
6-501.11 / PHYSICAL FACILITIES - GOOD REPAIR Core Item Repeat The ceiling in the"back" kitchen/storage area has extreme damage from a leak in an apartment above. Ceiling tiles are water damaged, missing, falling in. Render all ceiling areas to be smooth, easily cleanable, to-code. Correct By: 05-Nov-2013 |
6-501.19 / CLOSING TOILET ROOM DOORS Core Item Toilet room doors are not kept closed. Keep toilet room doors closed except during cleaning and maintenance operations. Correct By: 05-Aug-2013 |
FL 289.2129 / Certification of managerial employee under program accredited by American national standards institute; rules. Core Item There is no certified foodservice manager (CFSM). You must have a managerial employee who has successfully completed an accredited food certification program. Correct By: 05-Nov-2013 |
Comments |
---|
KELLY WAS THE PIC AT AN OPERATIONAL EVALUATION CONDUCTED TODAY. DENNY, OWNER, WAS HERE PART OF THE TIME, ALSO. SEVEN (7) CORE VIOLATIONS WERE CITED. THIS AGED FACILITY OVERALL WAS FOUND TO BE SANITARY & ORDERLY. THERE IS A HEALTH POLICY IN EFFECT. GOOD PRACTICES & PROCEDURES, SUCH AS PROPER EMPLOYEE DRINKING CONTAINERS; NO BARE HANDS CONTACTING READY-TO-EAT FOODS; AND THE PROPER MANUAL WAREWASH PROCESS, WERE NOTED. THE BASEMENT, WHERE THE AIR GAPPING FOR THE ICE MAKER & SOUTHERMOST ICE BIN WOULD BE CHECKED, IS NOT ACCESSIBLE DUE TO REPEATED FLOODING. |