| Facility Type: | Fast Food Restaurant |
| Inspection type: | Routine |
| Inspection date: | January 23, 2013 |
| Number of critical violations: | 2 |
| Number of non-critical violations: | 4 |
Definition of critical and non critical violations
| Code | Observation / Corrective Action |
| 43.1-3-4(a)-(h) | The person in charge (PIC) has a valid certificate of successful completion of a Certified Food Manager (CFM) exam but does not possess the CFM card issued by ORS Interactive, Inc. Food managers who possess a valid certificate of passing a food safety exam shall obtain the photo identification card from ORS Interactive, Inc. (see handout provided) within 10 business days. A copy of the photo identification card can be faxed to the food safety section at (703) 385-9568. Failure to provide a copy of the photo identification card will result in further enforcement action. |
| 6-301.14 | Corrected During Inspection Observed that sign or poster that notifies food employees to wash their hands is not provided at bathroom handwashing sink used by food employees. Provide a sign or poster at all handwashing sinks used by food employees that reminds food employees to wash their hands. |
| 4-501.114(C) | Corrected During Inspection Critical When tested, the quaternary ammonium compound-based sanitizing solution was observed to be at a concentration less than what is required for effective sanitization of food-contact surfaces of equipment and utensils. Observed the sanitizing solution in the 3 vat sink with a concentration of 0 ppm total quaternary ammonium compound. CFM corrected quat solution to 200 ppm. The quaternary ammonium sanitizer used in this facility shall have a minimum concentration of at least 200 ppm OR a concentration between 150-400ppm based on the manufacturer's use directions and using the appropriate test kit. |
| 7-202.12(A)(1)-(4) | Corrected During Inspection Critical Pesticides labeled for residential use were observed in the facility and are being applied by the operator to control pests: can of roach spray. cfm discarded item Remove residential use pesticides from the facility. When necessary for pest control, chemical pesticides must be applied by a certified pesticide applicator to prevent injury and contamination. |
| 4-601.11(C) | The nonfood-contact surfaces of the following equipment were observed soiled with an accumulation of dust, dirt, food residue, and/or other debris: true 2dr cooler Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue and other debris to maintain a sanitary work environment and prevent pest attraction. |
| 6-501.110(A) | Employees are not using the dressing rooms or lockers provided. Instruct employees to use the designated dressing rooms to prevent contamination of food, food equipment and utensils, and preparation surfaces. |