[?] Violations: A summary of the violations found during the inspection are listed below. |
4-203.11 / TEMPERATURE MEASURING DEVICES, FOOD - ACCURACY Thermometer used in middle food prep unit is not accurate to +/- 2°F Replace thermometer. |
4-501.11 / GOOD REPAIR, PROPER ADJUSTMENT, AND OPERATION Kick plate/cover on the 1-door server cooler is in poor repair. Repair kick plate. |
4-601.11(C) / NON-FOOD CONTACT SURFACES Bulk storage bins and chip buckets are not clean on the outside to sight and touch. Clean storage bins and chip buckets. |
5-205.15(B) / PLUMBING SYSTEM MAINTAINED IN GOOD REPAIR Drain cover is not installed to protect the floor drain beside the dishwasher. Install drain cover or drain net. |
5-205.15(B) / PLUMBING SYSTEM MAINTAINED IN GOOD REPAIR Faucet fixture on mop sink is leaking. Repair fixture. |
6-202.14 / TOILET ROOMS, ENCLOSED Employee toilet room is not provided with a tight fitting self-closing door Provide a self- closing door mechanism on bathroom door to provide a tight fitting self closing door. |
6-501.12 / CLEANING, FREQUENCY AND RESTRICTIONS Floors have build-up of grease/food in hard-to-reach areas under and around equipment, and on the wheels of equipment. Clean the physical facilities at a frequency necessary to keep them clean. |