3701-31-04 (B)(3) / Staff is trained and knowledgeable
Observed that the staff is not well trained or knowledgeable out the pool maintenance.
In order to reduce the risk of health hazards, ensure that the staff is trained in pool operations, operation of equipment, chemical storage, use and handling and appropriate emergency procedures. Recommend have an operator take a certified pool operator course.
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Observed that the emergency device (telephone) was not working.
In order to reduce the risk of safety hazards, ensure that the emergency device is functioning properly and rings to the emergency response authorities. Repair/replace the phone.
3701-31-04(D)(6)(a)(1) / Combined chlorine shall not exceed 1.0 ppm.
Observed that the combined chlorine was at 10.0 ppm.
In order to reduce the risk of health hazards, the combined chlorine shall not exceed 1.0 ppm. Treat the pool so that the combined chlorine is less than 1 ppm.
Facility Type: Pool
[?] Inspection Type: Follow-up
Inspection Date: 03-April-2019
Comments |
---|
Combined chlorine is still too high. Asked operator was he has done over the past couple of days to correct the issues. He stated that he back washed the pool, added some fresh water and added some more chlorine. He stated that he was unable to located a cartridge for the filter. Before the follow up tomorrow, the filter cartridge needs to be replaced, back wash the pool again, and perform a superchlorination. Raise the free cholorine to 10x the amount of combined chlorine. Also recommend getting a FAS-DPD testing kit for the pool so that they can sufficiently test the high levels of free chlorine for the superchlorination. |