3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8. Observed a pH of 8.0.
Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (C)(7) / Spa water temperature is less than 104 degrees Fahrenheit/ thermometer is provided
Repeat Corrected During Inspection Observed the spa water temperature to be 105 degrees F.
PIC turned down the temperature of the spa.
3701-31-04(D)(6)(a)(1) / Combined chlorine shall not exceed 1.0 ppm.
Combined chlorine was greater than 1.0 ppm. Observed a combined chlorine of 2.4 ppm
Treat the pool so that the combined chlorine is less than 1 ppm.
Facility Type: Spa
[?] Inspection Type: Complaint
Inspection Date: 27-January-2017
Comments |
---|
Received a complaint that the facility is dirty. Facility was clean upon inspection. Observed some orange discoloration (stains) within the whirlpool area, which may have been confused as dirt/debris. Discoloration/stains likely appeared over time from unbalanced water. Observed the whirlpool temperature to be elevated at 105 degrees F. Observed the pH to be elevated at 8.0. Combined chlorine was also elevated at 2.4ppm. Spoke with PIC about the issue. Spa temperature was turned down. Further maintenance of the whirlpool will be taken care of by the operator. |