3701-31-04 (E)(2)(a)(ii) / A USCG Type IV personal flotation device with 30 -60 foot throw line provided
Observed that the A USCG Type IV personal flotation device with 30 -60 foot throw line is severely torn/damaged
In order to reduce the risk of safety hazards, ensure that a USCG Type IV personal flotation device with a 1/4" diameter thick 30-60 ft rope in good repair is provided. Provide a proper floatation device at all times.
3701-31-04 (E)(2)(d) / First aid kit provided
Observed an empty first aid kit.
In order to reduce the risk of health hazards, ensure that a first aid kit is readily available to the public at all times. Provide first aid equipment, including a first aid kit, at the pool at all times. The first aid kit needs to supplied with sufficient supplies to stop bleeding and disposable gloves.
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Observed that the emergency telephone was not working.
In order to reduce the risk of safety hazards, ensure that the emergency device is functioning properly and rings to the emergency response authorities.
Facility Type: Pool
[?] Inspection Type: Follow-up
Inspection Date: 05-July-2019
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 (D)(7)(c)/Audible/visual alarm shall activate when unit is malfunctioning or when pH or ORP levels are not acceptable. Observed that the ACC was in alarm. In order to reduce the risk of health hazards, ensure that the ACC is no longer in alarm. Have the ACC unit serviced or replaced so that the audible or visual alarm is activated when necessary. |