3701-31-04 (B)(4)(a)(ii) / Combined chlorine is tested daily at pool side prior to use
Observed combined chlorine not being tested every 12 hours when maintenance personnel is not available.
Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use. Ensure pool chemicals are tested every 12 hours when pool is open.
3701-31-04 (B)(4)(a)(iii) / pH is tested daily at pool side at required intervals for pools/automatic chemical controllers/special features
Observed pH not being tested every 12 hours when maintenance personnel is not available.
pH must be tested prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use pH must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the pH must be tested at 1 special feature every 6 hours the sprayground or spray feature is in use. Ensure pool chemicals are tested every 12 hours when the pool is open.
3701-31-04 (B)(6)(a) / Pool structure is water tight
Repeat Observed several missing wall tiles on the inside of the pool.
Repair/replace the missing wall tiles.
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Observed the door to the outside was not self-closing and lockable.
Repair the door in order to be self-closing and lockable.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 12-December-2019