[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(d) / Circulation/Disinfection system is operating properly
Critical Disinfection system was not operating properly at the time of the inspection due to the salt disinfection system having to be sent back to the manufacturer.
Do not operate the pool when disinfection system is not operating properly. Ensure that the disinfection system is functioning properly prior to placing the pool back into operation.
3701-31-04 (B)(1)(e) / Automatic Chemical Controller (ACC) is functioning properly
Critical Automatic Chemical Controller (ACC) was not functioning properly at the time of the inspection. The salt disinfection system was not hooked up and operational.
Do not operate the pool when the ACC unit is not functioning properly. Ensure that the ACC unit is functioning properly prior to placing the pool back into operation.
3701-31-04 (C)(5) / Deepest point of the public swimming pool is readily visible from the deck
Water clarity was so poor that the deepest portion of the pool was not clearly visible.
Do not operate the pool when water clarity is poor. Improve the water clarity so that the bottom of the pool is clearly visible at all times. Please improve the water clarity.
3701-31-04 (D)(5) / Cyanuric acid level does not exceed 70 ppm
Cyanuric acid level exceeded 70 ppm.
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly.


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 11-June-2014