No critical violations were documented at the time of inspection.
No violations were documented at the time of inspection.
Facility Type: Pool
[?] Inspection Type: Follow-up
Inspection Date: 26-October-2023
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 (B)(1)(d)/Circulation/Disinfection system shall operate properly. Observed the flow to be at zero. In order to ensure proper chemical composition of the facility’s pool over time, the flow of the pool must not be inhibited. Discussed with person in charge, who called maintenance and closed the pool until conditions improved. |
3701-31-04 (B)(1)(e)/Automatic Chemical Controller (ACC) shall function properly. Observed an alarm on the Automatic Chemical Controller (ACC). In order to ensure proper chemical composition of the facility’s pool over time, ACC must be operational when the pool is open. Discussed with person in charge, who closed the pool. |
3701-31-04 (B)(4)/The licensee /authorized representative is keeping records Observed that records of only some of the chemical results were maintained. In order to ensure proper chemical composition of the facility’s pool over time, chemical pool records must be maintained regularly. Discussed with person in charge, and drew up examples of record keeping during the inspection. |
3701-31-04 (E)(2)(a)(ii)/A USCG Type IV personal flotation device with 30 -60 foot throw line provided Observed the personal flotation device with a throw line greater than 60ft. In order to reduce the risk of physical harm to patrons of the pool, ensure that the personal flotation device has a 30-60ft throw line. Discussed with person in charge. |
3701-31-04(D)(6)(a)(2)/Pool free chlorine disinfectant residual shall be above 1 ppm. Observed the pool free chlorine disinfectant residual to be at 0ppm. In order for proper disinfection to take place, ensure that the pool free chlorine disinfectant residual is maintained above 1ppm. Discussed with person in charge. |