3701-31-04 (B)(6)(e) / Equipment identification labels are maintained or on file
The Pump identification labels was difficult to read because of past exposure to water.
Replace the missing equipment labels or have the proper equipment information on site for each piece of equipment. The operator indicated that a replacement label could be supplied.
3701-31-04 (B)(6)(p) / Deck surfaces are free of standing water or other hazards.
Several areas on the deck surface had small cracks.
Repair areas of the deck where it is cracked or missing. The operator had repair supplies on site and was scheduled to repair the deck within the next few days.
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
The inside gate to the wading pool from the larger, life-guard supervised area did not always self-latch.
Repair the perimeter gate so that it self-latches. The operator had plans to adjust the tilt of the latch so it would self-latch
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 22-May-2014
Comments |
---|
Wading pool scheduled to open the following weekend. |