3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8. Observed pH to be above 8.0.
Treat the pool water so that the pH is within the acceptable range. Adjust the pH of the pool to be within 7.2-7.8.
Facility Type: Pool
[?] Inspection Type: Follow-up
Inspection Date: 02-September-2015
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04(D)(6)(a)(3)/Pool bromine disinfectant residual shall be above 2 ppm. Pool bromine disinfectant residual was below 2 ppm. Observed disinfectant residual to be 0 ppm. Do not operate the pool until the bromine disinfectant residual is at 2 ppm or above. Adjust the level of the bromine disinfectant residual to be at 2 ppm or above using automatic chemical controller, or manually add secondary chlorine disinfectant to 1 ppm or above. Do not operate the pool until the disinfectant residual is at the proper level. |