3701-31-04 (B)(1)(g) / Water clarity shall be sufficient to see the pool bottom (or Secchi disc).
Critical Water clarity was not sufficient to see the pool bottom (or Secchi disc). Observed that jets were not observable from the other side of the pool.
In order to reduce the risk of patron safety, do not operate the pool when water clarity is poor.
3701-31-04 (B)(3) / Staff is trained and knowledgeable
Repeat Observed that staff was not trained or knowledgeable in pool operations.
In order to reduce the risk of improper pool maintenance, train staff in pool operations, operation of equipment, chemical storage, use and handling and appropriate emergency procedures.
3701-31-04(D)(6)(a)(1) / Combined chlorine shall not exceed 1.0 ppm.
Repeat Combined chlorine was greater than 1.0 ppm. Observed a combined chlorine of 2ppm.
In order to reduce the risk of improper pool disinfection, treat the pool so that the combined chlorine is less than 1 ppm.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 31-July-2019