[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Gate was not self closing.
Repair the perimeter barrier so that there are not any gaps greater than 4 inches anywhere along the barrier. Correct to make gate self-closing.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8, and was above 8.
Treat the pool water so that the pH is within the acceptable range. Add acid.
3701-31-04 (E)(3)(c) / Location of emergency telephone posted when the phone is not visible.
Sign indicating the location of the emergency device (telephone) was not provided and emergency device was not visible in the pool area.
Ensure that a sign informing patrons of the location of the emergency device is always visible in the pool area. Add sign.


Inspection Information


Facility Type: Spa

[?] Inspection Type: Standard

Inspection Date: 15-October-2015