[?] A summary of the violations found during the inspection are listed below.

3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
Observed the ORP reading was at 550 mv.
The ORP reading was below 650 mv. Have the ACC unit inspected to determined why the ORP is low.
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Repeat Observed that the total alkalinity was not tested at least once a week.
The total alkalinity was not tested weekly. Test total alkalinity at least once/week.


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 24-July-2018

Comments
Recommend replacing the backboard, wood is splintering.