3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Corrected During Inspection pH was outside the range of 7.2 to 7.8. Observed pH to be above 8.0.
PIC added muriatic acid to bring down the pH.
Facility Type: Pool
[?] Inspection Type: Follow-up
Inspection Date: 05-August-2015
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04(D)(6)(a)(1)/Combined chlorine shall not exceed 1.0 ppm. Combined chlorine was greater than 1.0 ppm. Observed combined chlorine to be 1.5 ppm. Treat the pool so that the combined chlorine is less than 1 ppm. Combined chlorine must be less than or equal to 1 ppm. Adjust the level to make it within acceptable range. |
3701-31-04(D)(6)(a)(2)/Pool free chlorine disinfectant residual shall be above 1 ppm. Pool free chlorine disinfectant residual was below 1 ppm. Observed free chlorine disinfectant residual to be 0.5 ppm. Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above. Adjust the levels of the disinfectant residual to be within acceptable range. |
Comments |
---|
Facility will be resurfacing pool and rerouting some of the pipeworks in the equipment room. Inspector will complete another pool equipment inventory in September (or when work is completed). |