3701-31-04 (B)(6)(p) / Deck surfaces are free of standing water or other hazards.
Observed deck surface to have missing tiles, creating standing water.
Repair areas of the deck where standing water is occuring. If more than 50% of the deck must be replaced, plans must be submitted to the Ohio Department of Health for review and approval. Repair or replace the damaged area of the deck.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was outside the range of 7.2 to 7.8. Observed pH to be above 8.0.
Treat the pool water so that the pH is within the acceptable range. Adjust pH to be within 7.2 - 7.8.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm. Observed alkalinity to be 40 ppm.
Raise the total alkalinity to at least 60 ppm. Adjust alkalinity to be within acceptable range.
3701-31-04 (C)(7) / Spa water temperature is less than 104 degrees Fahrenheit/ thermometer is provided
Repeat Observed spa water temperature to be 105.3 degF.
Adjust spa water temperature to be less than 104 degF.
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 07-March-2016