3701-31-04 (B) / All facilities are maintained clean, safe and sanitary condition and in good repair.
Observed the step stools in the women's and men's restrooms need to be cleaned and not have dirt or soil on the treads of the stools if it is planned to keep the stools by the sinks for small kids to reach the sinks.These need to be kept clean as part of maintaining the restrooms/changing rooms clean to reduce the risk of exposure to dirt or bacteria (especially when in contact with bare feet and used by the small kids)
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH measured at 7.0. It needs to be in the range of 7.2 to 7.5. to allow swimming in the pool and to be at the correct pH level for the Chlorine to work as a sanitizer/disinfectant.
3701-31-04 (E)(2)(a)(i) / 12 ft. non-telescopic reach pole with shepherd's crook is provided
Corrected During Inspection Need to have the shepherd crook (hook) out at the pool and not in the life guard's office to be easily found by lifeguards or pool patrons to use quickly to assist a swimmer who is having difficulties swimming or drowning. Crook was brought out during the inspection to correct.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 23-May-2023
Comments |
---|
Flow meter(s) There are 3 flow meters on the water line for the main pool. None of the meter's flow indicator was working. Saw flow in the pool from vents and movement in the hair and lint trap. Need to fix the flow meter used to measure the flow. Replaced 2 sand filters. Note the base of the toilet in the men's restroom/changing room has small fine line cracks and should be monitored for leaks or the cracks becoming bigger that the toilet will need to be replaced. At the time of the inspection, the toilet was functioning and not leaking. |