[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(5) / Records are maintained for at least two years
Observed the daily logs to be incomplete and not fully filled-in.
Maintain all records and have them available upon request. All daily logs must be fully completed daily, with the pool's name and address, the dates, the characteristics of the pool filled in, the times when the pool water is tested noted, the pool measurements noted correctly, all corrective actions noted, and all other required notes. Complete the records from previous days and start making complete records today.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8. pH measured at 7.0.
Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm. Alkalinity measured at 45-50 ppm.
Raise the total alkalinity to at least 60 ppm.


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 22-July-2014