3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Chlorine disinfectant residual was less than 1 ppm for the pool
Do not operate the pool when the disinfectant residuals are less than what is required. Ensure the chlorine disinfectant residual is at 1 ppm or above prior to placing the pool back into operation.
3701-31-04 (B)(1)(d) / Circulation/Disinfection system shall operate properly.
Critical Circulation system was not operating properly at the time of the inspection
Do not operate the pool when the circulation system is not operating properly. Ensure that the circulation system is functioning properly prior to placing the pool back into operation.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
The pH was tested to be 8.0.
Treat the pool water so that the pH is within the acceptable range of 7.2 to 7.8.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 16-November-2017
Comments |
---|
A repair person is scheduled to fix the pump casing on either Tuesday or Wednesday (11/21 or 11/22). Operations manager Carla Hobbs will call if she is able to get the repair person sooner and have the pool operational. |