3701-31-04 (D)(7)(c) / Audible/visual alarm shall activate when unit is malfunctioning or when pH or ORP levels are not acceptable.
Critical Observed that the ACC was in alarm.
In order to reduce the risk of health and safety hazards, ensure that the ACC alarm is repaired and the ACC is functioning and reading properly. .
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Observed that the emergency device (telephone) was not working.
In order to reduce the risk of health and safety hazards, ensure that the emergency device is functioning properly. Repair/replace the phone.
Facility Type: Pool
[?] Inspection Type: Follow-up
Inspection Date: 15-April-2019
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04(D)(6)(a)(1)/Combined chlorine shall not exceed 1.0 ppm. Observed that the combined chlorine was at 2.0 ppm. In order to reduce the risk of health hazards, treat the pool so that the combined chlorine is less than 1 ppm. |
Comments |
---|
ACC still in alarm mode. Continue monitoring the pool every 4 hours until the ACC is functioning properly. Recommend contacting a professional and having the ACC serviced and repaired. Also, ensure that the emergency phone is repaired/replaced. |