3701-31-04 (D)(8)(b) / FAS-DPD test kit used (when standard DPD test kit insufficient)
FAS-DPD test kit was not used when required. Test kit only able to test chlorine to 10ppm,chlorine tested @ 12ppm.
Obtain a FAS-DPD test kit immediately. PIC to lower chlorine below 10ppm making test kit capable of measuring parameters.
Facility Type: Pool
[?] Inspection Type: Follow-up
Inspection Date: 25-May-2018
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 (B)(6)/Equipment is maintained per manufacturers specifications. Equipment was not maintained per manufacturers specifications. Observed non-functioning pressure gauge on sand filter. All equipment must be maintained in accordance with the manufacturers specifications. PIC to replace gauge. |
3701-31-04 (C)(3)/Total alkalinity is at or greater than 60 ppm Total alkalinity was less than 60 ppm.Observed Total alkalinity @40ppm. Raise the total alkalinity to at least 60 ppm. PIC to add alkalinity booster to bring above 60ppm. |