3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Weir is missing in pool filters
All equipment must be maintained in accordance with the manufacturers specifications.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
The covers of the filters were broken and not properly secured. The tiles and the surface of the pool were broken and in a state of disrepair.
All equipment must be maintained in accordance with the manufacturers specifications. Repair/replace any broken equipment so that it is maintained in good repair.
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Observed ladder to have a broken step and not be securely fixed to pool deck.
Repair or replace the ladders/stairs/steps so that it is maintained in good repair and securely fixed to pool deck.
Facility Type: Pool
[?] Inspection Type: Follow-up
Inspection Date: 06-November-2017
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 (B)(1)(a)/Outlet covers shall be installed/secured/in compliance There is a pool drain that does not have the required outlet cover. Do not operate the pool when the outlet covers are not installed. |
3701-31-04 (B)(6)(c)/Cross connection hazards shall be prevented. The outet for the discharge pipe was underneath of the flood rim of the drain in the pump room. Remove all cross connection hazards from the pump room by raising the air gap for the discharge pipe, so that it is above the flood room of the drain. |
3701-31-04 (B)(6)(c)(ii)/Backwash lines and lines from drainage sumps shall have an air gap and remain open to freely drain. Backwash lines and lines from drainage sumps did not have an air gap prior to discharge Open the lines that discharge into the backwash or drainage sumps so that there is an air gap and the lines can drain freely. |
3701-31-04 (B)(6)(h)/Required meters and gauges maintained/functional Flow meter wasn't functioning. Maintain all meters and gauges in a properly funtioning manner at all times while the pool is in operation. Repair/replace the flow meter so that it provides an accurate reading. |