3701-31-04 (B)(1) / Public swimming pool operates free of an imminent health hazard
Critical Corrected During Inspection Observed spa temperature to be 105.3 degrees F.
Do not operate the pool when an imminent health hazard is present. SPa temepratures above 105 degrees F is an immenent health hazard. Water was added to the spa, reducing the temperature to 103.6.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was > 8.0.
pH must be within the range of 7.2 to 7.8. Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was ~10 ppm.
Total alkalinity must be at least 60 ppm. Raise the total alkalinity to at least 60 ppm.
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 28-March-2014
Comments |
---|
While not a violation, the bromine residual was measured to be excessively high at 30 ppm. Bromine in a spa is only required to be 4.0 ppm. Recommend the bromine is decreased to a lower value. |