3701-31-04 (B)(4)(a)(i) / Disinfection residuals are tested daily at pool side at required intervals for pools/automatic chemical controllers/special features
Disinfection residuals were not tested daily at pool side and/or at the required intervals for pools/automatic chemical controllers/special features. Observed disinfectant residual to be untestable using standard comparator tube.
Test the disinfection residual every day before bathers enter the water. Disinfection residual must then be tested every 4 hours when an ACC is not in use. If an ACC is in use the disinfectant residual must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the disinfectant residual must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use. Management is in the process of finding another company/individual to assist with operating ACC. Disinfectant residual must be testable poolside using standard comparator tube.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 28-July-2015
Comments |
---|
Spoke with lifeguard about high level of chlorine. Maintenance man recently quit and they are in contact with another pool management agency to assist with chemical regulation of the pool. Inspector unable to test disinfectant residual using standard comparator tube due to high level of disinfectant residual in pool. |