3717-1-02.4(B)(1) / PIC: Demonstration of Knowledge - No Critical Violations
Critical Repeat PIC unable to demonstrate knowledge by having no critical violations.OBSERVED CRITICAL VIOLATIONS AT TIME OF INSPECTION. THE OPERATOR SHALL MAINTAIN CONTROL AND OVERSIGHT OF THE OPERATION TO ENSURE THAT CRITICAL VIOLATIONS DO NOT OCCUR.
3717-1-04.5(A)(1) / Cleanliness of equipment food-contact surfaces and utensils.
Critical Corrected During Inspection Equipment food-contact surfaces or utensils are unclean. OBSERVED A BUILD UP OF DEBRIS ON THE UPPER INTERIOR PANEL OF THE ICE MACHINE. TO PREVENT CONTAMINATION, FOOD CONTACT SURFACES SHALL BE CLEAN TO SIGHT AND TOUCH.
3717-1-03.4(F)(1)(b) / Time/temperature controlled for safety food - cold holding.
Critical Corrected During Inspection TCS foods not being cold held at the proper temperature.OBSERVED THE FOLLOWING TCS FOODS HELD AT IMPROPER TEMPERATURES ON THE PREP LINE:
-SAUSAGE:63*F
-POTATOES:61*F
TO LIMIT THE GROWTH OF PATHOGENS THAT MAY CAUSE A FOODBORNE ILLNESS, TCS FOODS SHALL BE HELD AT 41 DEGREES F OR BELOW IN COLD HOLDING
3717-1-02.4(A)(2) / PIC - Manager Certification
Repeat Facility does not have an employee with manager certification in food protection. OBSERVED NO MANAGER/SUPERVISOR WITH AN OHIO FOOD MANAGERS CERTIFICATION.
3717-1-03.5(C)(1) / Food labels - packaged food
A food packaged in the facility not labeled. OBSERVED PACKAGED FOOD ITEMS (DELI SANDWICHES) STORED IN THE GRAB N GO COOLER WITHOUT A LABEL.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard/Critical Control Point
Inspection Date: 06-January-2022
Comments |
---|
CRITICAL CONTROL POINT INSPECTION VII - Protection from Contamination: Equipment food-contact surfaces or utensils are dirty.OBSERVED A BUILD UP OF DEBRIS ON THE UPPER INTERIOR PANEL OF THE ICE MACHINE. TO PREVENT CONTAMINATION, FOOD CONTACT SURFACES SHALL BE CLEAN TO SIGHT AND TOUCH. VI - TCS Food: TCS foods were not being held at the proper temperature.OBSERVED THE FOLLOWING TCS FOODS HELD AT IMPROPER TEMPERATURES ON THE PREP LINE: -SAUSAGE:63*F -POTATOES:61*F TO LIMIT THE GROWTH OF PATHOGENS THAT MAY CAUSE A FOODBORNE ILLNESS, TCS FOODS SHALL BE HELD AT 41 DEGREES F OR BELOW IN COLD HOLDING |