3717-1-02.4(B)(1) / PIC: Demonstration of Knowledge - No Critical Violations
Critical PIC unable to demonstrate knowledge by having no critical violations. OBSERVED THERE TO BE CRITICAL VIOLATIONS AT THE TIME OF INSPECTION. PERSON IN CHARGE MUST MAINTAIN OVERSIGHT OF OPERATION TO ENSURE THAT CRITICAL VIOLATIONS DO NOT OCCUR.
3717-1-03.4(F)(1)(b) / Time/temperature controlled for safety food - cold holding.
Critical Corrected During Inspection TCS foods not being cold held at the proper temperature. OBSERVED SUBWAY MAKE TABLES TO BE HOLDING TCS FOODS BETWEEN 49F AND 69F. ALL ITEMS WERE DISCARDED AND IDENTIFIED ON THE VOLUNTARY DESTRUCTION FORM.
3717-1-03.4(F)(1)(b) / Time/temperature controlled for safety food - cold holding.
Critical Corrected During Inspection TCS foods not being cold held at the proper temperature. OBSERVED WALK-IN COOLER TO BE HOLDING TCS FOODS (SUBWAY ITEMS) BETWEEN 43F AND 56F.
3717-1-05.1(D) / Backflow prevention - air gap.
Critical Insufficient air gap between the flood rim and the water supply inlet. OBSERVED PREP SINK DRAIN TO NOT BE PROPERLY AIR-GAPPED. DRAIN PIPE SHOULD BE SHORTENED TO HAVE AN AIR GAP OF AT LEAST TWO TIMES THE DIAMETER OF THE PIPE.
3717-1-04.2(A) / Equipment - cooling, heating, and holding capacities.
Inadequate equipment available for cooling, heating or holding food. OBSERVED ALL MAKE TABLES AND WALK-IN COOLER TO BE HOLDING TCS FOODS AT INADEQUATE TEMPERATURES DURING INSPECTION. MAINTENANCE CALLS WERE PLACED FOR SAME DAY SERVICE.
3717-1-04.8(E)(2) / Clean equipment and utensils stored in a self-draining position and covered or inverted.
Clean equipment and utensils not stored in a self-draining position and covered or inverted.
OBSERVED PLASTIC THIRD PANS STORED ON SHELVING ON SUBWAY SIDE NOT INVERTED.
3717-1-04.4(A)(2) / Equipment components kept intact, tight, and adjusted
Equipment components are not intact, tight or properly adjusted. OBSERVED WALK-IN COOLER TO HAVE A BROKEN HINGE CAUSING THE DOOR TO NO LONGER CLOSE.
3717-1-04.5(D) / Nonfood-contact surfaces - cleaning frequency.
Non-food contact surface(s) not cleaned at the required frequency. OBSERVED CONVENIENCE SIDE DRINK STATION CABINETS TO HAVE INTERIOR SPILLAGE.
3717-1-05.1(S) / Plumbing system - maintained in good repair.
Plumbing system not properly maintained or repaired. OBSERVED HANDSINK IN 7-ELEVEN AREA TO BE LEAKING FROM THE BOTTOM OF THE CABINET.
3717-1-05.1(B)(1) / Approved plumbing system.
Plumbing system does not comply with the Ohio plumbing code. OBSERVED SUBWAY POP MACHINE TO BE DRAINING INTO A BUCKET.
3717-1-05.4(H) / Toilet room receptacle - covered.
No covered receptacle in women's restroom. OBSERVED WASTE BIN IN WOMEN'S RESTROOM TO BE MISSING LID.
3717-1-06.4(B) / Cleaning - frequency and restrictions.
Facility not maintained clean. OBSERVED FLOOR UNDERNEATH SUBWAY POP DISPENSER TO HAVE AN ACCUMULATION OF DIRT AND DEBRIS.
Facility Type: Commercial RFE < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 09-March-2023
Comments |
---|
Facility is undergoing ownership change and being rebranded from 7-Eleven. This inspection will also serve as a compliance inspection. The Subway portion will remain unchanged but all 7-Eleven branded equipment (coolers, beverage dispenser, hot dog rollers) and menu items are being removed from the convenience portion of the store. |