3717-1-02.4(C)(10) / Person in charge: duties - ensure employees are properly sanitizing equipment and utensils
Critical The person in charge did not ensure that employees are properly sanitizing equipment or utensils.
To prevent contamination, the person in charge shall ensure that employees are properly sanitizing cleaned multiuse equipment and utensils before they are reused.
>>Disassemble meat slicer, wash, rinse and sanitize every 4 hours minimum.
3717-1-02.4(C)(14) / Person in charge: duties - ensure employees are informed in a verifiable manner of their responsibility to report their health information
Critical Person in charge did not ensure that employees are informed in a verifiable manner of their responsibility to report information about their health.
To prevent transmission of foodborne illness, the person in charge shall ensure that food and conditional employees are informed in a verifiable manner of their responsibility to report information about their health as it relates to diseases that are transmissible through food.
3717-1-02.4(C)(9) / Person in charge: duties - ensure consumers who order raw or undercooked foods are provided a consumer advisory
Critical The person in charge did not ensure that consumers who order raw or partially cooked animal foods are informed that the food was not cooked sufficiently to ensure its safety.
To prevent foodborne illness, the person in charge shall ensure that consumers who order raw or partially cooked ready to eat animal foods are informed that the food was not cooked sufficiently to ensure its safety.
>>Selling raw air dried sausage as a ready to eat food without a consumer advisory. Discontinue selling raw air dried sasuage without a variance.
3717-1-03.1(A)(1) / Sources - compliance with food law.
Critical Observed foods that are from an unapproved source.
To prevent foodborne illness, food shall be obtained from sources that comply with law.
>>Observed bakery being sold that is suspected to be from an unapproved source due to improper labelling and declaration of allergens. Remove bakery from sale until sources are confirmed and proper labelling is provided. PIC was not confident that the source of the food was approved. Foods include: Ponnies Potica, pumpkin roll, Sofies bakery and Barbs bakery.
3717-1-03.2(C) / Packaged and unpackaged food - preventing contamination by separation, packaging, and segregation
Critical Observed food that was not properly protected from contamination by separation, packaging, and segregation.
To prevent contamination, food shall be protected from cross contamination by separating raw animal foods during storage, preparation, holding, and display from cooked ready-to-eat food as described in this rule.
>>Observed raw animal foods including sasuage casings and eggs stored above ready to eat foods in the walk-in cooler.
3717-1-03.4(G) / Ready-to-eat, time/temperature controlled for safety food - date marking.
Critical Corrected During Inspection Refrigerated, ready-to-eat, TCS foods held refrigerated for more than 24 hours were not properly date marked.
To prevent foodborne illness, refrigerated, ready-to-eat, TCS food held at a temperature of 41°F or less for more than 24 hours shall be clearly marked at the time of preparation or the time the original container is opened to indicate the date or day, that is a maximum of seven days, by which the food shall be consumed, sold, or discarded. The day the food is prepared or opened is day one.
>>Provide Date Marking on bulk lunch meats and packaged products in deli case and smoked meat in walk-in cooler stored in bins. A food specified under this rule must be discarded if it is in a container or package that does not bear a date or day.
3717-1-03.4(J) / Variance requirement.
Critical Observed a process that requires a variance and no variance was obtained.
To prevent foodborn illness, an FSO or RFE shall obtain a variance before: 1) Smoking food as a method of food preservation rather than as a method of flavor enhancement; (2) Curing food; (3) Except as provided in rule 3717-1-08.4 of this code, using food additives or adding components such as vinegar as a method of food preservation rather than as a method of flavor enhancement, or to render a food so that it is not a TCS food; (4) Packaging TCS food using a reduced oxygen packaging method except where the growth of Clostridium botulinum and Listeria monocytogenes are controlled as specified under paragraph (K) of this rule; (5) Operating a molluscan shellfish life-support system display tank used to store or display shellfish that are offered for human consumption; (6) Custom processing of animals that are for personal use as food and not for sale or service in a FSO or RFE if the processing is not done in compliance with rule 3717-1-08.2 of this code; (7) Pressing or bottling juice unless the processing is done in compliance with rule 3717-1-08 of this code; (8) Use of a heat treatment dispensing freezer in a manner other than as specified in rule 3717-1-08.1 of this code; (9) Preparing food by another method that is determined by the Ohio department of health or Ohio department of agriculture to require a variance; or (10) Sprouting seeds or beans.
>>Apply for a variance with ODA for air dried italian sausage and salami, air dried slovenian sausage and salami.
3717-1-03.4(K) / Reduced oxygen packaging - criteria.
Critical Observed improper packaging of food using reduced oxygen packaging without a variance.
To prevent the growth of pathogens: (1) Except for an FSO or RFE obtains a variance, an FSO or RFE that packages TCS food using a reduced oxygen packaging method shall control the growth and toxin formation of Clostridium botulinum and the growth of Listeria monocytogenes; (2) An FSO or RFE that packages TCS food using reduced oxygen packaging shall have a HACCP plan; (3) Except for fish that is frozen before, during and after packaging, an FSO or RFE may not package fish using a reduced oxygen packaging method; (4) An FSO or RFE that packages food using a cook-chill or sous vide process without obtaining a variance shall implement a HACCP plan, ensure that: the food is properly cooled as specified in this rule, held in refrigeration equipment with a system that continually monitors the time and temperature, and ensure that all records are maintained; (5) An FSO or RFE that packages cheeses using reduced oxygen packaging shall: (a) limit the cheeses packaged to those that are commercially manufactured in a food processing plant with no ingredients added in the FSO or RFE and that meet the standards of identity; (b) Have a HACCP plan, (c) Labels the package on the principal display panel with a use by date that does not exceed thirty days or the manufacturer's sell by or use by date, whichever occurs first; and (d) discards the reduced oxygen packaged cheese if it is not sold or consumed within thirty calendar days of its packaging.
>>Provide a HACCP plan for ROP foods and ROP foods that are repackaged (ham, sausages). Label foods with proper date.
3717-1-03.5(E) / Consumer advisory.
Critical The consumer is not properly advised of the risk of consuming raw or undercooked animal foods.
To properly inform consumers, except for whole-muscle intact beef steaks, if an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish is served or sold raw, undercooked, or without otherwise being processed to eliminate pathogens, either in ready-to-eat form, or as a raw ingredient in another ready-to-eat food, the license holder shall inform consumers of the significantly increased risk of consuming such food by way of a disclosure and reminder using brochures, deli-case or menu advisory, label statements, table tents, placards, or other effective written means.The reminder shall include asterisking the animal-derived foods requiring disclosure to a footnote that states: (1) Regarding the safety of these items, written information is available upon request; (2) Consuming raw or undercooked meats, poultry seafood, shellfish, or eggs may increase your risk of foodborne illness; or (3) Consuming raw or undercooked meats, poultry seafood, shellfish, or eggs may increase your risk of foodborne illness, especially if you have certain medical conditions.
>>Selling raw air dried sausage without a consumer advisory. Discontinue selling raw air dried sausage without a variance.
3717-1-04.5(B) / Equipment food-contact surfaces and utensils - cleaning frequency.
Critical Food equipment surfaces are not cleaned at the required frequency.
Equipment food-contact surfaces and utensils shall be cleaned at a frequency specified in this rule.
>>Meat slicers must be disassembled and cleaned every 4 hours minimum.
3717-1-07.2 / Poisonous or toxic materials: storage and display - separation
Critical Observed improper display or storage of poisonous or toxic materials offered for retail sale.
To prevent contamination, poisonous or toxic materials shall be stored so they cannot contaminate food, equipment, utensils, linens, single-service articles, or single use articles by separating the poisonous or toxic materials, and locating the poisonous or toxic materials in an area that is not above food, equipment, utensils, linens, single-service articles, or single-use articles.
>>Discontinue storing chemicals on shelf next to smoker above clean food containers.
3717-1-02.4(C)(16) / Person in charge: duties - ensure the facility has written procedures for vomiting and diarrheal events.
Person-in-charge did not ensure that the facility has written procedures for employees to follow when responding to vomiting or diarrheal events..
Person in charge shall ensure that the FSO or RFE have written procedures for employees to follow when responding to vomiting or diarrheal events that involved discharge onto surfaces.
3717-1-03. / Food - safe, unadulterated, and honestly presented
Corrected During Inspection Observed food that was unsafe, adulterated, or not honestly presented.
To prevent foodborne illness, food shall be safe, unadulterated, and honestly presented.
>>Observed foods being made and sold without an approved variance including air dried slovenian sausage and salami, air dried raw italian sausage and salami. Foods were voluntarily discarded at time of inspection. (see Voluntary Destruction of Unfit Products form attached)
3717-1-03.2(Y) / Miscellaneous sources of contamination.
Miscellaneous sources of contamination observed.
Food shall be protected from contamination that is not specified under 3717-1-03.2 (A) to (X).
>>Discontinue storing food under condensing unit that is dripping condensate in walk-in freezer.
One tray of contaminated breakfast sausage was voluntarily discarded at time of inspection
3717-1-03.2(Y) / Miscellaneous sources of contamination.
Miscellaneous sources of contamination observed.
Food shall be protected from contamination that is not specified under 3717-1-03.2 (A) to (X).
>>Discontinue storing power equipment such as snowblower, lawnmower, etc. in the walk-in cooler that is used periodically for food storage.
3717-1-03.5(C)(2) / Food labels - packaged food
A label on a food packaged in the RFE or FSO did not contain all required information.
Foods shall be labeled as specified in this rule.
>>Label information shall include:
(a) The common name of the food, or absent a common name, an adequately descriptive identity statement;
(b) If made from two or more ingredients, a list of ingredients and sub-ingredients in descending order of predominance by weight, including a declaration of artificial colors, artificial flavors and chemical preservatives, if contained in the food;
(c) An accurate declaration of the quantity of contents;
(d) The name and place of business of the manufacturer, packer, or distributor; and
(e) The name of the food source for each major food allergen contained in the food unless the food source is already part of the common or usual name of the respective ingredient.
(f) Except as exempted in the Federal Food, Drug, and Cosmetic Act Section
>>Labelling on the homebakery items did not include the required labelling info. Remove all bakery items from sale until proper labelling is provided. Labels were missing allergens, subingredients,place of business of manufacturer, etc.
3717-1-04.1(K) / Food temperature measuring devices - accuracy.
Food thermometers are not accurate to plus or minus one degree C, or plus or minus two degrees F in the intended range of use.
To prevent foodborne illness, food temperature measuring devices that are scaled only in Celsius or dually scaled in Fahrenheit and Celsius shall be accurate to plus or minus one degree Celsius in the intended range of use; Food temperature measuring devices that are scaled only in Fahrenheit shall be accurate to plus or minus two degrees Faranheit in the intended range of use.
>>Repair/Replace non working probe thermometer.
3717-1-04.2(B)(1) / Manual warewashing - three compartment sink required.
Observed no three-compartment sink for the manual washing, rinsing, and sanitizing of utenils.
To prevent contamination, a sink with at least three compartments shall be provided for manually washing, rinsing and sanitizing equipment and utensils.
3717-1-04.2(B)(4) / Manual warewashing - two compartment sink requirements.
Facility is using an unapproved two-compartment sink or the two-compartment sink is being used in an unauthorized manner.
Before a two-compartment sink is used, the license holder shall: have its use approved by the licensor; limit the number of kitchenware items cleaned and sanitized in the sink; limit warewashing to batch operations; make up the cleaning and sanitizing solutions immediately before use and drain them immediately after use; and use an approved detergent-sanitizer or a hot water sanitzation immersion step as described in this code.
3717-1-05.4(F)(1) / Outside receptacles - tight fitting lids
Observed outdoor refuse containers without tight fitting lids, doors, or covers.
Receptacles and waste handling units for refuse, recyclables, or returnables used outside with materials containing food residue, shall be designed and constructed to have tight-fitting lids, doors, or covers.
>>Dumpster lids not tight fitting due to overfilled dumpster. Increase pickup frequency or dumpster size to accomodate refuse.
3717-1-06.1(A) / Floors, walls, and ceilings.
Floors, walls, and/or ceilings were not smooth and easily cleanable.
Floors, floor coverings, walls, wall coverings, and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable.
>>Floors in prep. room need sealed or resurfaced to be easily cleanable.
Facility Type: Commercial RFE < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 22-August-2017