3717-1-03.4(C) / Thawing - temperature and time control.
Repeat Corrected During Inspection TCS foods not properly thawed. ROP packages of fish were thawing and sealed. When thawing ROP fish the package must be opened.
3717-1-04.2(H)(2) / Temperature measuring devices - mechanical warewashing.
Repeat Irreversible registering temperature indicator not readily accessible for hot water mechanical warewashing operations.
3717-1-06.4(B) / Cleaning - frequency and restrictions.
Facility not maintained clean. The ceiling is soiled in the dishwashing area.
3701-21-25(I) / Person in charge certification in food protection
Repeat FSO did not have a person in charge per shift with the person in charge certification in food protection.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard/Critical Control Point
Inspection Date: 14-January-2020
Comments |
---|
I - P - Employee Health: The operation had an employee health policy on file. IV - P - Demonstration of Knowledge: The person in charge is Certified in Food Protection. VI - P - TCS Food: Observed hot foods being held at 135°F or above; cold foods being held at 41°F or below. VI - P - TCS Food: Observed ready to eat TCS foods being properly date marked, and discarded when required. VIII - P - Consumer Advisory: Observed a consumer advisory on the menu for animal foods that are served raw, undercooked or not otherwise processed to eliminate pathogens. |