3717-1-03.2(J) / Food contact with equipment and utensils
Critical Observed food in contact with an unclean surface.
MUSROOMS WERE COMING IN CONTACT WITH UNCLEAN PANS.
To prevent contamination, food shall only contact the surfaces of cleaned and sanitized equipment and utensils or single-use and/or single-service articles.
MUSHROOMS WERE DISCARDED AT THE TIME OF INSPECTION.
3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical TCS foods were not being held at the proper temperature.
MUSHROOMS WERE BEING COLD HELD AT 55 DEGREES F.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
3717-1-03.5(E) / Consumer advisory.
Critical The consumer is not properly advised of the risk of consuming raw or undercooked animal foods.
To properly inform consumers, except for whole-muscle intact beef steaks, if an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish is served or sold raw, undercooked, or without otherwise being processed to eliminate pathogens, either in ready-to-eat form, or as a raw ingredient in another ready-to-eat food, the license holder shall inform consumers of the significantly increased risk of consuming such food by way of a disclosure and reminder using brochures, deli-case or menu advisory, label statements, table tents, placards, or other effective written means.The reminder shall include asterisking the animal-derived foods requiring disclosure to a footnote that states: (1) Regarding the safety of these items, written information is available upon request; (2) Consuming raw or undercooked meats, poultry seafood, shellfish, or eggs may increase your risk of foodborne illness; or (3) Consuming raw or undercooked meats, poultry seafood, shellfish, or eggs may increase your risk of foodborne illness, especially if you have certain medical conditions.
3717-1-05.1(D) / Backflow prevention - air gap.
Critical Observed the air gap between a plumbing fixture and a piece of equipment that was not sufficient to prevent back siphonage of contaminated water.
INSUFFICIENT AIR GAP AT THE BAR THREE COMPARTMENT SINK.
To prevent contamination, an air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment, or nonfood equipment shall be at least twice the diameter of the water supply inlet and may not be less than one inch (25 millimeters). Correct By: 20-Nov-2015
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 10-November-2015