3717-1-02.4(B)(2)(f) / PIC: Demonstration of Knowledge - Stating required temperatures and times for safe cooking of TCS food
Critical Corrected During Inspection OBSERVED PERSON IN CHARGE (PIC) DID NOT RESPOND CORRECTLY TO THE SANITARIANS QUESTIONS REGARDING FOOD SAFETY. TO DEMONSTRATE KNOWLEDGE, THE PIC MUST STATE THE REQUIRED FOOD TEMPERATURES FOR SAFE COOKING OF TCS FOOD.
3717-1-02.4(B)(1) / PIC: Demonstration of Knowledge - No Critical Violations
Critical Corrected During Inspection OBSERVED PERSON IN CHARGE (PIC) DID NOT COMPLY WITH THE CODE BY HAVING NO CRITICAL VIOLATIONS DURING CURRENT INSPECTIONS. TO EXERCISE MANAGERIAL CONTROL OVER THE FOOD SERVICE OPERATION, IT IS MANDATORY THAT THE PERSON IN CHARGE (PIC) COMPLY WITH THE CODE BY HAVING NO CRITICAL VIOLATIONS DURING THE CURRENT INSPECTION. THE SANITARIAN EDUCATED THE PIC ON WAYS TO PREVENT CRITICAL VIOLATIONS DURING SUBSEQUENT INSPECTIONS.
3717-1-02.4(C)(15) / PIC: duties - ensure employees are informed in a verifiable manner of their responsibility to report their health information
Critical AN EMPLOYEE HEALTH POLICY IS NOT PROVIDED FOR THE FOOD SERVICE OPERATION. FOOD EMPLOYEES ARE NOT INFORMED IN A VERIFIABLE MANNER OF THEIR RESPONSIBILITY TO REPORT TO THE PERSON IN CHARGE (PIC) INFORMATION ABOUT THEIR HEALTH AS IT RELATES TO COMMUNICABLE DISEASE AND DISEASES THAT ARE TRANSMISSIBLE THROUGH FOOD. TO PREVENT THE SPREAD OF DISEASE, IT IS MANDATORY THAT THE PIC ENSURES THAT THE EMPLOYEES ARE AWARE OF REPORTING THE REQUIREMENTS FOR COVID-19 SYMPTOMS, MAJOR SYMPTOMS OF CONCERN SUCH AS DIARRHEA AND JAUNDICE AND THE THIRTEEN REPORTABLE DISEASES. THE INSPECTOR PROVIDED UPDATED HEALTH POLICY WHICH INCLUDES COVID-19 SYMPTOMS TO THE PIC. SANITARIAN INSTRUCTED THE PIC TO SECURE SIGNATURES OF EMPLOYEES ON A SHIFT WITH A COMMITMENT TO PROVIDE POLICY COPIES FOR ALL BACK-OF-HOUSE (BOH) EMPLOYEE.
3717-1-04.1(KK) / Food equipment - certification and classification.
Equipment not approved by a recognized testing agency (SANITARIAN OBSERVED A NON-COMMERCIAL STANDING FREEZER IN THE BASEMENT THAT MUST BE REPLACED BY JULY 31, 2024).
3717-1-06.2(I)(1) / Lighting - intensity (10 FC)
Light intensity less than ten foot candles in required areas (OBSERVED THERE WERE ONLY SIX FOOT CANDLES IN THE FRONT OF THE WALK-IN COOLER AND ONE FOOT CANDLE IN THE REAR).
3717-1-06.2(I)(3) / Lighting - intensity (50 FC)
Light intensity less than fifty foot candles in required areas (OBSERVED TWENTY-THREE FOOT CANDLES ON THE MAIN COOKING LINE).
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard/30 Day/CCP
Inspection Date: 25-January-2024
Comments |
---|
THE STANDING NON-COMMERCIAL CHEST FREEZER IN THE BASEMENT MUST BE REPLACED BY JULY 31, 2024. |
III - P - Preventing Contamination by Hands: Hand washing facilities are properly supplied. VI - P - TCS Food: Observed hot foods being held at 135°F or above; cold foods being held at 41°F or below. I - Employee Health: Person in charge did not ensure that employees are informed of their responsibility to report information about their health. AN EMPLOYEE HEALTH POLICY IS NOT PROVIDED FOR THE FOOD SERVICE OPERATION. FOOD EMPLOYEES ARE NOT INFORMED IN A VERIFIABLE MANNER OF THEIR RESPONSIBILITY TO REPORT TO THE PERSON IN CHARGE (PIC) INFORMATION ABOUT THEIR HEALTH AS IT RELATES TO COMMUNICABLE DISEASE AND DISEASES THAT ARE TRANSMISSIBLE THROUGH FOOD. TO PREVENT THE SPREAD OF DISEASE, IT IS MANDATORY THAT THE PIC ENSURES THAT THE EMPLOYEES ARE AWARE OF REPORTING THE REQUIREMENTS FOR COVID-19 SYMPTOMS, MAJOR SYMPTOMS OF CONCERN SUCH AS DIARRHEA AND JAUNDICE AND THE THIRTEEN REPORTABLE DISEASES. THE INSPECTOR PROVIDED UPDATED HEALTH POLICY WHICH INCLUDES COVID-19 SYMPTOMS TO THE PIC. SANITARIAN INSTRUCTED THE PIC TO SECURE SIGNATURES OF EMPLOYEES ON A SHIFT WITH A COMMITMENT TO PROVIDE POLICY COPIES FOR ALL BACK-OF-HOUSE (BOH) EMPLOYEE. |