3717-1-04.2(G)(1) / Food temperature measuring devices - availability
Critical Repeat A food thermometer was not readily accessible.
PIC DOES DID NOT HAVE A THERMOMETER.
To prevent foodborne illness, food temperature measuring devices shall be provided and readily accessible for use. Correct By: 01-Jun-2015
3717-1-04.2(I) / Sanitizing solutions - testing devices.
Critical Repeat There is no test kit available for measuring the concentration of the sanitizer.
To ensure proper sanitization, a test kit or other device that accurately measures the concentration in PPM (mg/L) of sanitizing solutions shall be provided. Correct By: 01-Jun-2015
3717-1-05(H) / Capacity.
Critical Repeat The water source and system is not of sufficient capacity to meet the peak water demands.
PIC INDICATED THAT WATER HEATER WAS MAINTANENCED OVER THE WEEKEND AND MAY BE THE CAUSE OF THE HANDSINK NOT ABLE TO MEAT THE MINIMUM TEMPERATURE REQUIREMENT.
To ensure proper cleaning and sanitation, the water source and system, hot water generation, and distribution systems shall be of sufficient capacity to meet the peak water and hot water demands of the FSO or RFE.
WATER HEATER MUST BE REPAIRED/OR ADJUSTED SO THE WATER IS ABLE TO REACH AT LEAST 100 DEGREES F. Correct By: 02-Jun-2015
3717-1-05.3(C) / Backflow prevention.
Critical Repeat Observed a direct connection between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed.
OBSERVED A DIRECT CONNECTION FROM 3 COMPARTMENT SINK TO SEWER DRAIN.
To prevent health hazards, a direct connection may not exist between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed unless allowed by the Ohio building code for: a warewashing machine between its waste outlet and a floor drain when the machine is located within five feet (1.5 meters) of a trapped floor drain and the machine outlet is connected to the inlet side of a properly vented floor drain trap; or a warewashing and culinary sink. Correct By: 08-Jun-2015
3717-1-05.3(I) / Other liquid wastes and rainwater.
Repeat Observed improper draining of condensation and other nonsewage liquids.
BASEMENT OF BUILDING APPEARED TO HAVE FLOODING ISSUES.
Condensate drainage and other nonsewage liquids and rainwater shall be drained from point of discharge to disposal according to law.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Follow-up
Inspection Date: 09-June-2015
Comments |
---|
FACILITY DOES NOT HAVE HOT WATER AND WAS STILL OPERATING. OPERATOR IS TO CEASE AND DESIST ALL OPERATION UNTIL HOT WATER TANK IS PROPERLY WORKING. |