3717-1-02.4(B)(1) / PIC: Demonstration of Knowledge - No Critical Violations
Critical OBSERVED PERSON IN CHARGE (PIC) DID NOT COMPLY WITH THE CODE BY HAVING NO CRITICAL VIOLATIONS DURING CURRENT INSPECTIONS. TO EXERCISE MANAGERIAL CONTROL OVER THE FOOD SERVICE OPERATION, IT IS MANDATORY THAT THE PERSON IN CHARGE (PIC) COMPLY WITH THE CODE BY HAVING NO CRITICAL VIOLATIONS DURING THE CURRENT INSPECTION. THE SANITARIAN EDUCATED THE PIC ON WAYS TO PREVENT CRITICAL VIOLATIONS DURING SUBSEQUENT INSPECTIONS.
3717-1-02.4(C)(15) / PIC: duties - ensure employees are informed in a verifiable manner of their responsibility to report their health information
Critical AN EMPLOYEE HEALTH POLICY IS NOT PROVIDED FOR THE FOOD SERVICE OPERATION. FOOD EMPLOYEES ARE NOT INFORMED IN A VERIFIABLE MANNER OF THEIR RESPONSIBILITY TO REPORT TO THE PERSON IN CHARGE (PIC) INFORMATION ABOUT THEIR HEALTH AS IT RELATES TO COMMUNICABLE DISEASE AND DISEASES THAT ARE TRANSMISSIBLE THROUGH FOOD. TO PREVENT THE SPREAD OF DISEASE, IT IS MANDATORY THAT THE PIC ENSURES THAT THE EMPLOYEES ARE AWARE OF REPORTING THE REQUIREMENTS FOR COVID-19 SYMPTOMS, MAJOR SYMPTOMS OF CONCERN SUCH AS DIARRHEA AND JAUNDICE AND THE THIRTEEN REPORTABLE DISEASES. THE INSPECTOR PROVIDED UPDATED HEALTH POLICY WHICH INCLUDES COVID-19 SYMPTOMS TO THE PIC. SANITARIAN INSTRUCTED THE PIC TO SECURE SIGNATURES OF EMPLOYEES ON A SHIFT WITH A COMMITMENT TO PROVIDE POLICY COPIES FOR ALL BACK-OF-HOUSE (BOH) EMPLOYEES.
3717-1-05.1(O)(1) / Using a handwashing sink - accessible at all times
Critical SANITARIAN OBSERVED HAND SINK WAS NOT EASILY ACCESSIBLE. TO ENCOURAGE FREQUENT WASHING OF HANDS, A HAND SINK MUST NOT BE BLOCKED FROM EASY ACCESS TO IT. SANITARIAN INSTRUCTED THE PERSON IN CHARGE (PIC) TO REMOVE ALL OF THE ITEMS WHICH IMPEDE ACCESS TO THE HAND SINK.
3717-1-07.1(A) / Poisonous or toxic materials: Storage: separation.
Critical Corrected During Inspection OBSERVED CHEMICALS STORED ABOVE OR NEXT TO FOOD. TO PREVENT CONTAMINATION OF FOOD, UTENSILS, OR SINGLE SERVICE ITEMS, THEY SHALL BE STORED SO THAT THERE IS NO CONTACT WITH POISONOUS OR TOXIC MATERIALS. TOXIC AND POISONOUS MATERIALS MUST BE SEPARATED SO THEY CANNOT CONTAMINATE FOOD. SANITARIAN INSTRUCTED THE PERSON IN CHARGE (PIC) TO PLACE TOXIC/POISONOUS SUPPLIES IN A SEPARATE STORAGE AREA.
3717-1-04.1(K) / Food temperature measuring devices - accuracy.
Critical OBSERVED DURING CALIBRATION THE BI-METALLIC PROBE THERMOMETER (BMPT) WAS THIRTY-EIGHT DEGREES FAHRENHEIT. TO ENSURE ALL FAHRENHEIT ONLY FOOD THERMOMETERS ARE READ ACCURATELY, BMPT MUST BE CALIBRATED TO WITHIN TWO DEGREES PLUS OR MINUS THIRTY-TWO DEGREES FAHRENHEIT FOR ICE POINT METHOD OR TWO HUNDRED AND TWELVE DEGREES FAHRENHEIT FOR BOILING POINT METHOD. SANITARIAN INSTRUCTED THE PERSON IN CHARGE (PIC) TO RECALIBRATE THE BMPT.
3717-1-04.4(I) / Manual warewashing equipment - wash solution temperature.
Critical Corrected During Inspection OBSERVED WASH SOLUTION IN THREE COMPARTMENT SINK WAS ONLY NINETY-NINE DEGREES FAHRENHEIT. TO DESTROY BACTERIA ON UTENSILS, POTS, PANS, ETC., IT IS MANDATORY THAT THE TEMPERATURE OF THE WASH SOLUTION BE MAINTAINED AT NO LESS THAN ONE HUNDRED AND TEN DEGREES FAHRENHEIT. SANITARIAN INSTRUCTED THE PERSON IN CHARGE (PIC) TO EMPTY THE SINK OR INCREASE THE WASH SOLUTION TO ONE HUNDRED AND TEN DEGREES FAHRENHEIT OR MORE.
3717-1-05.3(C) / Sewage and other liquid waste: Backflow prevention.
Critical OBSERVED THE CULINARY SINK DRAIN LINE WAS NOT PROPERLY AIR GAPPED. TO PREVENT BACKFLOW AND CONTAMINATION OF THE FOOD AND EQUIPMENT, IT IS MANDATORY THAT THE DRAIN LINE SHALL BE AT LEAST ONE INCH ABOVE THE FLOOR DRAIN. SANITARIAN INSTRUCTED THE PERSON IN CHARGE (PIC) TO ENSURE THAT THE DRAIN LINE IS ONE INCH ABOVE THE FLOOR DRAIN.
3717-1-02.4(C)(17) / PIC: duties - ensure the facility has written procedures for responding to vomiting and diarrheal events.
No written procedures for responding to vomiting or diarrheal events (OBSERVED THERE WAS NO SPILL KIT).
3717-1-02.3(A) / Food contamination prevention - eating, drinking, or using tobacco.
Corrected During Inspection Employee eating, drinking, or using tobacco in non-designated area (OBSERVED AN OPEN BEVERAGE CONTAINER).
3717-1-06.2(E) / Handwashing signage.
Corrected During Inspection Handwashing sign(s) not posted.
3717-1-04.1(Y) / Temperature measuring devices.
Hot and cold holding equipment thermometer was missing, located incorrectly, or not easily readable (OBSERVED THERE WERE COOLERS MISSING THERMOMETERS. ALL THERMOMETERS SHOULD BE PLACED IN THE FRONT OF THE COOLER).
3717-1-02.3(C) / Hair restraints - effectiveness.
Corrected During Inspection Food employee(s) not wearing a hair restraint.
3717-1-04.3(B) / Fixed equipment installation - spacing or sealing.
Fixed equipment not properly sealed or spaced for cleaning (OBSERVED THE THREE COMPARTMENT SINK, THE HAND SINK, AND THE CULINARY SINK NEED TO BE PROPERLY SEALED TO THE WALL).
3717-1-04.2(I) / Sanitizing solutions - testing devices.
No sanitizer test kit available (OBSERVED SANITIZER TEST STRIPS WERE EXPIRED).
3717-1-05.4(H) / Toilet room receptacle - covered.
Corrected During Inspection No covered receptacle in women's restroom.
3717-1-06.4(F) / Drying mops.
Corrected During Inspection Mops dried improperly.
3717-1-06.4(N) / Maintaining premises - unnecessary items and litter.
Unnecessary or nonfunctional items and /or litter on premises.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 21-August-2023
Comments |
---|
THERE ARE SEVERAL PIECES OF NON-COMMERCIAL EQUIPMENT. WHEN THAT EQUIPMENT BREAKS, IT MAY ONLY BE REPLACED WITH COMMERCIAL EQUIPMENT. |