3717-1-02.1(A) / Employee health: Reporting by food employees
Critical License holder did not require employee(s) to report symptoms, an illness diagnosed by a health care provider, or high risk situations as specified by law.OPERATION DID NOT HAVE AN EMPLOYE HEALTH POLICY.
To prevent the transmission of foodborne illnesses, the license holder shall require food employees and conditional employees to report to the person in charge information about their health as it relates to diseases that are transmissible through food.OPERATION SHOULD HAVE AN EMPLOYEE HEALTH POLICY WITH THE 13 REPORTABLE DISEASES AND COMMON SYMPTOMS FOR FOOD EMPLOYEE TO SIGN.
3717-1-02.4(B) / Person in charge: demonstration of knowledge.
Critical The person in charge was unable to demonstrate proper knowledge of food safety and prevention. OBSERVED CRITICAL VIOLATIONS AT TIME OF INSPECTION.
To prevent or correct factors that may cause foodborne illness, based on the risks inherent to the food operation, during inspections and upon request, the person in charge shall demonstrate to the licensor the applicable food safety knowledge at the time of inspection.OPERATOR SHALL MAINTAIN CONTROL AND OVERSIGHT OF THE OPERATION TO ENSURE THAT CRITICAL VIOLATIONS DO NOT OCCUR.
3717-1-03.2(C) / Packaged and unpackaged food - preventing contamination by separation, packaging, and segregation
Critical Corrected During Inspection Observed food that was not properly protected from contamination by separation, packaging, and segregation.OBSERVED RAW EGGS STORED OVER READY TO EAT FOOD IN THE REACH IN COOLER.
To prevent contamination, food shall be protected from cross contamination by separating raw animal foods during storage, preparation, holding, and display from cooked ready-to-eat food as described in this rule.TO PREVENT THE GROWTH OF PATHOGENS THAT MAY CAUSE A FOODBORNE ILLNESS, FOOD SHALL BE STORED ACCORDING TO THE MINIMUM COOKING REQUIREMENTS
3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical Corrected During Inspection TCS foods were not being held at the proper temperature. OBSERVED TCS FOOD (POLLO ASADO) HELD AT 129 DEGREES F IN HOT HOLDING.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.TO PREVENT THE GROWTH OF PATHOGENS THAT MAY CAUSE A FOODBORNE ILLNESS, TCS FOODS SHALL BE HELD AT 41 DEGREES F OR BELOW OR 135 DEGREE OR ABOVE.
3717-1-03.4(G) / Ready-to-eat, time/temperature controlled for safety food - date marking.
Critical Corrected During Inspection Refrigerated, ready-to-eat, TCS foods held refrigerated for more than 24 hours were not properly date marked. OBSERVED DELI MEAT (PASTRAMI) NOT DATEMARKED.
To prevent foodborne illness, refrigerated, ready-to-eat, TCS food held at a temperature of 41°F or less for more than 24 hours shall be clearly marked at the time of preparation or the time the original container is opened to indicate the date or day, that is a maximum of seven days, by which the food shall be consumed, sold, or discarded. The day the food is prepared or opened is day one.TO PREVENT THE GROWTH OF PATHOGENS THAT MAY CAUSE A FOODBORNE ILLNESS, TCS FOODS SHALL BE PROPERLY DATEMARKED IF HELD MORE THAN 24 HOURS AND SERVED/DISCARDED WITHIN 7 DAYS.
3717-1-03.5 (C)(2)(e) / Food labels - label information
Critical Observed packaged product(s), labeled on-site, with a missing and/or incomplete allergen declaration(s). OBSERVED COOKIES AND PASTRIES WITHOUT AN ALLERGEN DECLARATION.
To prevent exposure to food allergens, food label information shall include the name of the food source for each major food allergen contained in the food unless the food source is already part of the common or usual name of the respective ingredient.TO PREVENT EXPOSURE TO ALLERGENS, COOKIES AND PASTRIES SHALL CONTAIN THE NAME OF THE FOOD ALLERGENS ON THE LABEL. Correct By: 27-Feb-2018
3717-1-07.1(A) / Poisonous or toxic materials: Storage: separation.
Critical Corrected During Inspection Observed improper storage of poisonous or toxic materials.OBSERVED RAID (NON COMMERCIAL INSECTICIDE) STORED NEXT TO SINGLE USE ITEMS (TO GO CONTAINERS).
To prevent contamination, poisonous or toxic materials shall be stored so they cannot contaminate food, equipment, utensils, linens, or single-service or single-use articles by: 1) Separating the poisonous materials by spacing or partitioning; and 2) Locating the poisonous or toxic materials in an area that is not above food, equipment, utensils, linens, single-service articles or single-use articles.TO PREVENT CHEMICAL CONTAMINATION, TOXIC CHEMICALS SHALL BE STORED AWAY FROM FOOD SINGLE USE ITEMS.
3717-1-02.4(A)(2) / Person in charge: assignment of responsibility.
Facility did not have one employee with supervisory and management responsibility and the authority to direct and control food preparation and service with level two certification in food protection.OPERATION DID NOT HAVE A MANAGER/SUPERVISOR WITH A LEVEL II CERTIFICATION
At least one employee that has supervisory and management responsibility and the authority to direct and control food preparation and service shall obtain the level two certification in food protection according to rule 3701-21-25 of the Administrative Code.
3717-1-02.4(C)(16) / Person in charge: duties - ensure the facility has written procedures for vomiting and diarrheal events.
Person-in-charge did not ensure that the facility has written procedures for employees to follow when responding to vomiting or diarrheal events.OPERATION DID NOT HAVE WRITTEN PROCEDURES FOR VOMIT/FECAL CLEAN UP.
Person in charge shall ensure that the FSO or RFE have written procedures for employees to follow when responding to vomiting or diarrheal events that involved discharge onto surfaces.
3717-1-03.5(C)(1) / Food labels - packaged food
A food packaged in the facility did not contain a label. OBSERVED GRAB AND GO FOOD ITEMS(COOKIES, PASTRIES) WITHOUT LABELS.
Foods shall be labeled as specified in this rule.
3717-1-04.2(I) / Sanitizing solutions - testing devices.
There is no test kit available for measuring the concentration of the sanitizer.OPERATION DID NOT HAVE A QUATERNARY AMMONIUM TEST KIT.
To ensure proper sanitization, a test kit or other device that accurately measures the concentration in PPM (mg/L) of sanitizing solutions shall be provided.
3717-1-05.1(C)(1) / Handwashing sink - required water temperature
Observed a handwashing sink without water at the required temperature.OBSERVED HANDSINK HOT WATER AT 86 DEGREES F.
To ensure proper cleaning of hands, a handwashing sink shall be equipped to provide water at a temperature of at least 100° F (thirty-eight degrees Celsius) through a mixing valve or combination faucet.
3717-1-05.1(S)(1) / Plumbing system - maintained in good repair.
The plumbing system was not properly repaired.OBSERVED A SEWAGE BACK UP IN THE BASEMENT.
To prevent health hazards, a plumbing system shall be repaired according to the Ohio building code.
3717-1-06.1(A) / Floors, walls, and ceilings.
Floors, walls, and/or ceilings were not smooth and easily cleanable. OBSERVED FLOORS, WALLS, AND CEILINGS THAT WERE NOT EASILY CLEANABLE.
Floors, floor coverings, walls, wall coverings, and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable.
3717-1-06.4(B) / Cleaning - frequency and restrictions.
Observed a build-up of dirt and debris.OBSERVED SOILED FLOORS, WALLS, AND CEILINGS THROUGHOUT THE FACILITY.
The physical facilities shall be cleaned as often as necessary to keep them clean, and cleaning shall be done during periods when the least amount of food is exposed.
Facility Type: Commercial RFE < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 22-February-2018
Comments |
---|
FOODS ARE RECEIVED FROM APPROVED SOURCES (DAVE'S, GFS, SAVE A LOT). PEST CONTROL-TERMINIX. PROVIDED PIC (PERSON IN CHARGE) WITH AN EMPLOYEE HEALTH POLICY, VOMIT/FECAL CLEAN UP PROCEDURES, AND VARIOUS FOOD SAFETY HANDOUTS. |