3717-1-05.1(D) / Backflow prevention - air gap.
Critical Observed the air gap between a plumbing fixture and a piece of equipment that was not sufficient to prevent back siphonage of contaminated water.( OBSERVED NONSUFFICIENT AIR GAP FOR ICE MACHINE USED IN THE OPERATION)
To prevent contamination, an air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment, or nonfood equipment shall be at least twice the diameter of the water supply inlet and may not be less than one inch (25 millimeters).( PROVIDE THE NECESSARY ADJUSTMENTS AND REPAIRS IN REGARDS TO ICE MACHINE) Correct By: 20-Sep-2017
3717-1-05.3(C) / Sewage and other liquid waste: Backflow prevention.
Critical Observed a direct connection between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed.( ICE MACHINE IN THE KITCHEN WITH OUT BACK FLOW PREVENTION)
To prevent health hazards, a direct connection may not exist between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed unless allowed by the Ohio building code for: a warewashing machine between its waste outlet and a floor drain when the machine is located within five feet (1.5 meters) of a trapped floor drain and the machine outlet is connected to the inlet side of a properly vented floor drain trap; or a warewashing and culinary sink.( PROVIDE THE NECESSARY ADJUSTMENTS AND REPAIRS TO ICE MACHINE IN REGARDS TO BACKFLOW PREVENTION) Correct By: 20-Sep-2017
Facility Type: Non-Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 20-September-2017