3717-1-02.4(B)(1) / PIC: Demonstration of Knowledge - No Critical Violations
Critical PIC unable to demonstrate knowledge by having no critical violations. OBSERVED CRITICAL VIOLATIONS AT THE TIME OF INSPECTION. TO EXERCISE MANAGERIAL CONTROL OVER THE FOOD SERVICE OPERATION, THE PIC SHALL COMPLY WITH THE CODE BY HAVING NO CRITICAL VIOLATIONS DURING THE CURRENT INSPECTION. AT THE TIME OF THE INSPECTION, THE SANITARIAN INSTRUCTED THE PIC REGARDING THE CORRECTIVE ACTIONS NEEDED TO ENSURE NO CRITICAL VIOLATIONS OCCUR ON SUBSEQUENT INSPECTIONS.
3717-1-02.4(B)(2)(i) / PIC: Demonstration of Knowledge - Identifying major food allergens
Critical PIC unable to demonstrate knowledge of major food allergens. OBSERVED THE PIC WAS NOT ABLE TO IDENTIFY THE MAJOR FOOD ALLERGENS. TO DEMONSTRATE KNOWLEDGE AND PREVENT ALLERGY ATTACKS OR ANAPHYLAXIS DUE TO EXPOSURE TO MAJOR ALLERGENS, THE PIC SHALL BE ABLE TO IDENTIFY THE MAJOR FOOD ALLERGENS. AT THE TIME OF THE INSPECTION, THE SANITARIAN PROVIDED THE PIC WITH INFORMATION AND DOCUMENTATION REGARDING THE MAJOR FOOD ALLERGENS.
3717-1-02.4(C)(7) / PIC: duties - ensure employees are properly cooking TCS foods.
Critical Person in charge did not ensure employees are properly cooking TCS foods and/or using thermometers as required. OBSERVED THE PERSON IN CHARGE (PIC) DID NOT PROPERLY DEMONSTRATE CALIBRATION OF THE FOOD TEMPERATURE MEASURING DEVICE. TO ACCURATELY MEASURE THE TEMPERATURE OF TCS FOOD, FOOD TEMPERATURE MEASURING DEVICES SHALL BE PROPERLY CALIBRATED. AT THE TIME OF THE INSPECTION, THE SANITARIAN INSTRUCTED THE PIC REGARDING PROPER THERMOMETER CALIBRATION TECHNIQUES AND PROVIDED THE PIC WITH SUPPORTING DOCUMENTATION.
3717-1-02.2 (C ) / Hands and arms: when to wash
Critical Corrected During Inspection Food employee(s) did not wash hands when required. OBSERVED FOOD EMPLOYEE DONNING SINGLE-USE GLOVES WITHOUT WASHING HANDS WHEN CHANGING TASKS. TO PREVENT CONTAMINATION OF FOOD WITH MICROORGANISMS THAT CAN LEAD TO ILLNESS, FOOD EMPLOYEES SHALL CLEAN THEIR HANDS AND EXPOSED PORTIONS OF THEIR ARMS IMMEDIATELY BEFORE ENGAGING IN FOOD PREPARATION, BEFORE DONNING GLOVES TO INITIATE A TASK THAT INVOLVES WORKING WITH FOOD, AND DURING FOOD PREPARATION AS OFTEN AS NECESSARY TO REMOVE SOIL AND CONTAMINATION AND TO PREVENT CROSS CONTAMINATION WHEN CHANGING TASKS, AND AFTER ENGAGING IN ANY OTHER ACTIVITIES THAT CONTAMINATE THE HANDS. AT THE TIME OF THE INSPECTION THE PIC INSTRUCTED THE EMPLOYEE TO WASH HANDS BEFORE DONNING GLOVES.
3717-1-05.1(O)(2) / Using a handwashing sink - other uses prohibited.
Critical Handwashing sink is being used for purposes other than handwashing. OBSERVED FOOD DEBRIS IN THE HANDWASHING SINK IN THE KITCHEN; SEVERAL ICE CREAM CONES WERE PLACED IN THE SINK BEFORE AND AFTER SANITARIAN ARRIVAL. TO PREVENT CROSS-CONTAMINATION WITH MICROORGANISMS THAT CAN LEAD TO FOODBORNE ILLNESS, THE HANDWASHING SINK SHALL BE USED SOLELY FOR HAND WASHING PURPOSES. AT THE TIME OF THE INSPECTION THE SANITARIAN INSTRUCTED THE PIC REGARDING THE PERMITTED AND THE PROHIBITED USES OF A HANDWASHING SINK.
3717-1-07.1(A) / Poisonous or toxic materials: Storage: separation.
Critical Improper storage of poisonous or toxic materials. OBSERVED POISONOUS AND TOXIC MATERIALS (FURNITURE PAINT SPRAY AND ROOM FRAGRANCE SPRAYS) WERE STORED ON THE SHELF NEXT TO ICE CREAM SPRINKLES AND DECORATIONS INSIDE THE UNIFORM CABINET. TO PREVENT CONTAMINATION OF FOOD WITH POISONOUS AND TOXIC SUBSTANCES SUCH AS FURNITURE PAINT AND ROOM FRAGRANCE, POISONOUS AND TOXIC MATERIALS SHALL BE STORED IN SUCH A WAY SO THAT THEY CANNOT CONTAMINATE FOOD, EQUIPMENT, UTENSILS, LINENS, SINGLE-SERVICE ARTICLES, AND SINGLE-USE ARTICLES. AT THE TIME OF THE INSPECTION, THE SANITARIAN INSTRUCTED THE PIC REGARDING THE PROPER STORAGE OF FOOD ITEMS.
3717-1-07.1(A) / Poisonous or toxic materials: Storage: separation.
Critical Improper storage of poisonous or toxic materials. OBSERVED POISONOUS AND TOXIC MATERIALS (JERGENS SHEA BUTTER AND JERGENS ULTRA HEALING MOISTURIZERS) WERE STORED ON TOP OF THE ICE MACHINE. TO PREVENT CONTAMINATION OF FOOD WITH POISONOUS AND TOXIC SUBSTANCES SUCH AS WINDEX AND CLEANER, POISONOUS AND TOXIC MATERIALS SHALL BE STORED IN SUCH A WAY SO THAT THEY CANNOT CONTAMINATE FOOD, EQUIPMENT, UTENSILS, LINENS, SINGLE-SERVICE ARTICLES, AND SINGLE-USE ARTICLES. THIS VIOLATION WAS NOT CORRECTED AT THE TIME OF THE INSPECTION.
3717-1-07.1(C) / Poisonous or toxic materials: Conditions of use.
Critical Improper use of a poisonous or toxic substance. OBSERVED A CAN OF RAID ANT AND ROACH STORED BY THE DOOR NEXT TO THE UNIFORM CABINET IN THE BACK STORAGE ROOM. TO PREVENT CONTAMINATION OF FOOD, EQUIPMENT, AND UTENSILS, AND MINIMIZE THE CHEMICAL HAZARD TO EMPLOYEES, ONLY INCIDENTAL USE PESTICIDES SUCH AS BEE AND WASP PESTICIDES ARE PERMITTED IN THE FOOD SERVICE OPERATION IN ORDER TO AVOID IMMEDIATE PERSONAL HARM. AT THE TIME OF THE INSPECTION THE SANITARIAN INSTRUCTED THE PIC REGARDING THE PERMITTED AND PROHIBITED USES OF PESTICIDES IN A FOOD SERVICE OPERATION.
3717-1-05.1(D) / Backflow prevention - air gap.
Critical Insufficient air gap between the flood rim and the water supply inlet. OBSERVED NO AIR GAP BETWEEN THE FAUCET SPOUT AND THE FLOOD RIM OF THE WAREWASHING SINK. TO PREVENT CONTAMINATION CAUSED BY BACKFLOW, THE AIR GAP BETWEEN THE WATER SUPPLY INLET AND THE FLOOD LEVEL RIM OF THE WAREWASHING SINK SHALL BE AT LEAST TWICE THE DIAMETER OF THE WATER SUPPLY INLET AND MAY NOT BE LESS THAN ONE INCH. AT THE TIME OF THE INSPECTION THE SANITARIAN INSTRUCTED THE PIC REGARDING THE AIR GAP REQUIREMENT FOR BACKFLOW PREVENTION.
3717-1-05.3(C) / Sewage and other liquid waste: Backflow prevention.
Critical Direct connection between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed. OBSERVED THE WALK-IN FREEZER CONDENSATE LINE IN THE BACK STORAGE ROOM WAS NOT PROPERLY AIR GAPPED. TO PREVENT CONTAMINATION CAUSED BY BACKFLOW, THE DRAIN ORIGINATING FROM EQUIPMENT IN WHICH FOOD, PORTABLE EQUIPMENT, OR UTENSILS ARE PLACED, SUCH AS A WALK-IN FREEZER, SHALL CONTAIN AN INDIRECT CONNECTION IN WHICH THE CONDENSATE LINE MUST BE AT LEAST ONE INCH ABOVE THE FLOOR DRAIN. THIS VIOLATION WAS NOT CORRECTED AT THE TIME OF THE INSPECTION.
3717-1-05.1(G) / Handwashing sinks-Number.
Inadequate number of handwashing sinks. OBSERVED NO HANDWASHING SINK PROVIDED IN THE KITCHEN, BUT ONE COMPARTMENT OF A FOUR-COMPARTMENT WAREWASHING SINK WAS USED FOR HANDWASHING.
3717-1-06.2(E) / Handwashing signage.
Handwashing sign(s) not posted. OBSERVED HANDWASHING SINK ON THE FOOD PREP SIDE DIDN’T HAVE SIGNAGE.
3717-1-07.1(M) / Medicines - restrictions and storage.
Unnecessary medicines and/or improper labeling/storing of medicines. OBSERVED BOTTLES OF MEDICINES (ACETAMINOPHEN AND ANTACID TABLETS) STORED ON TOP OF THE ICE MACHINE.
3717-1-04.1(Y) / Temperature measuring devices.
Hot and cold holding equipment thermometer was missing, located incorrectly, or not easily readable. OBSERVED AN INTERNAL TEMPERATURE MEASURING DEVICE FOR THE WALK-IN COOLER HOLDING TIME/ TEMPERATURE CONTROLLED FOR SAFETY (TCS) FOOD WAS NOT PROVIDED.
3717-1-03.2(D) / Food storage containers - identified with common name of food.
Working food containers not properly labeled. OBSERVED WORKING CONTAINERS SUCH AS SQUEEZE BOTTLES HOLDING CONDIMENTS SUCH AS KETCHUP, MUSTARD, AND MAYO, WERE UNLABELED IN THE WALK-IN COOLER AND IN COLD-HOLDING AT HOT DOG PREP UNIT.
3717-1-03.2(Q) / Food storage - preventing contamination from the premises.
Improper storage of food items. OBSERVED FROZEN TURKEYS, DQ SANDWICH BOX, AND BETTERCREME FROSTINGS STORED DIRECTLY ON THE FLOOR IN THE WALK-IN FREEZER IN THE BACK STORAGE ROOM.
3717-1-03.2(Q) / Food storage - preventing contamination from the premises.
Improper storage of food items. OBSERVED ICE CREAM SPRINKLES AND DECORATIONS STORED INSIDE THE UNIFORM CABINET.
3717-1-04.8(E)(1) / Equipment, utensils, linens - storage.
OBSERVED BOXES OF SINGLE-SERVICE ITEMS SUCH AS 6-INCH SANDWICH CONTAINERS, AND PAPER BAGS, WERE STORED IN THE BACK STORAGE ROOM DIRECTLY ON THE FLOOR.
3717-1-04.2(I) / Sanitizing solutions - testing devices.
Corrected During Inspection No sanitizer test kit available. OBSERVED PROVIDED SANITIZER TEST STRIPS EXPIRED IN OCTOBER 2015 (QUATERNARY AMMONIUM TEST STRIPS).
3717-1-05.4(G) / Storage areas, rooms, and receptacles - capacity and availability.
Adequate area and/or receptacles for refuse, recyclables, or returnables not provided. OBSERVED HANDWASHING SINK IN THE KITCHEN WAS NOT PROVIDED WITH A TRASH RECEPTACLE.
3717-1-06.4(N) / Maintaining premises - unnecessary items and litter.
Unnecessary or nonfunctional items and /or litter on premises. OBSERVED OLD RESTROOM OFF THE BACK STORAGE ROOM FILLED TO THE TOP WITH LITTER (CARDBOARD BOXES, PIECES OF METAL SHELVING, AND DEBRIS).
3717-1-06.2(I)(3) / Lighting - intensity (50 FC)
Light intensity less than fifty foot candles in required areas. OBSERVED LIGHT INTENSITY MEASURED 22-25 FOOT-CANDLE (FC) AT HOT DOG PREP UNIT IN THE KITCHEN.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard/Critical Control Point
Inspection Date: 11-January-2023
Comments |
---|
VI - P - TCS Food: Observed hot foods being held at 135°F or above; cold foods being held at 41°F or below. I - P - Employee Health: The operation had an employee health policy on file. III - Preventing Contamination by Hands:Food employee(s) did not wash hands in situations that specifically require them to do so. OBSERVED FOOD EMPLOYEE DONNING SINGLE-USE GLOVES WITHOUT WASHING HANDS WHEN CHANGING TASKS. TO PREVENT CONTAMINATION OF FOOD WITH MICROORGANISMS THAT CAN LEAD TO ILLNESS, FOOD EMPLOYEES SHALL CLEAN THEIR HANDS AND EXPOSED PORTIONS OF THEIR ARMS IMMEDIATELY BEFORE ENGAGING IN FOOD PREPARATION, BEFORE DONNING GLOVES TO INITIATE A TASK THAT INVOLVES WORKING WITH FOOD, AND DURING FOOD PREPARATION AS OFTEN AS NECESSARY TO REMOVE SOIL AND CONTAMINATION AND TO PREVENT CROSS CONTAMINATION WHEN CHANGING TASKS, AND AFTER ENGAGING IN ANY OTHER ACTIVITIES THAT CONTAMINATE THE HANDS. AT THE TIME OF THE INSPECTION THE PIC INSTRUCTED THE EMPLOYEE TO WASH HANDS BEFORE DONNING GLOVES. X - Chemical: Observed toxic materials improperly identified, stored and used. OBSERVED A CAN OF RAID ANT AND ROACH STORED BY THE DOOR NEXT TO THE UNIFORM CABINET IN THE BACK STORAGE ROOM. TO PREVENT CONTAMINATION OF FOOD, EQUIPMENT, AND UTENSILS, AND MINIMIZE THE CHEMICAL HAZARD TO EMPLOYEES, ONLY INCIDENTAL USE PESTICIDES SUCH AS BEE AND WASP PESTICIDES ARE PERMITTED IN THE FOOD SERVICE OPERATION IN ORDER TO AVOID IMMEDIATE PERSONAL HARM. AT THE TIME OF THE INSPECTION THE SANITARIAN INSTRUCTED THE PIC REGARDING THE PERMITTED AND PROHIBITED USES OF PESTICIDES IN A FOOD SERVICE OPERATION. |