[?] A summary of the violations found during the inspection are listed below.

3717-1-05.1(D) / Backflow prevention - air gap.
Critical Observed the air gap between a plumbing fixture and a piece of equipment that was not sufficient to prevent back siphonage of contaminated water. THE PRE-RINSE FAUCET (SPRAYER) ON THE 3 COMPARTMENT SINK HANGS BELOW THE FLOOD RIM OF THE SINK. THERE NEEDS TO BE AN AIR GAP PRESENT ACCORDING TO THE FOLLOWING STANDARD: To prevent contamination, an air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment, or nonfood equipment shall be at least twice the diameter of the water supply inlet and may not be less than one inch (25 millimeters).
To prevent contamination, an air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment, or nonfood equipment shall be at least twice the diameter of the water supply inlet and may not be less than one inch (25 millimeters).

3717-1-05.1(S)(2) / Plumbing system - maintained in good repair.
The plumbing system was not properly maintained. THE HANDWASHING SINK NEAREST THE DRIVE THROUGH WINDOW HAS A SLOW LEAK ON THE GASKET AROUND THE DRAIN PIPE. THE MANAGER IS AWARE AND IS GOING TO PLACE A MAINTENANCE REQUEST.
A plumbing system shall be properly maintained.


Inspection Information


Facility Type: Commercial FSO < 25000 sq. ft.

Inspection Type: Standard

Inspection Date: 03-January-2017


Comments
SANITIZER AND TEST STRIPS- OK
DATE MARKING- OK
ALL COLD HOLDING IS AT OR BELOW 41F AND ALL HOT HOLDING IS AT OR ABOVE 135F.