3717-1-02.2(G) / Jewelry - prohibition.
Food employees wearing jewelry on arms or hands (bracelets) during food preparation.
3717-1-04.4(A)(2) / Equipment components kept intact, tight, and adjusted
Equipment components are not intact, tight or properly adjusted. Display refrigeration unit in disrepair. TCS food shall not be placed in the equipment and until it can maintain the product below 41 degrees F.
3717-1-04.2(C) / Drainboards.
Repeat Insufficient storage space provided for soiled and clean items.
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment.
Non-food contact surfaces of the ice machine and turbo chef were not free of visible soil, residue, or debirs. If utensils are being stored on these surfaces they both shall be warewashed/ cleaned and sanitized at the required frequency.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 01-March-2023
Comments |
---|
The violations documented shall be corrected and will be checked during next standard inspection. |