3717-1-03.4(G) / Ready-to-eat, time/temperature controlled for safety food - date marking.
Critical Corrected During Inspection Refrigerated, ready-to-eat, TCS foods held refrigerated for more than 24 hours (hash browns) were not properly date marked.
Refrigerated, ready-to-eat, TCS food held refrigerated for more than 24 hours shall be clearly marked at the time of preparation or the time the original container is opened to indicate the date or day to be consumed, sold, or discarded as required in this rule. Employee discarded the hash browns at the time of inspection.
3717-1-03.4(H)(1) / Ready-to-eat, time/temperature controlled for safety food - disposition.
Critical Ready-to-eat, TCS food (cooked chicken wings) that had been date marked was not properly discarded when required.
To prevent illness refrigerated, ready-to-eat TCS food that has been date marked in the facility shall be discarded if it exceeds the temperature or time except the time the food is frozen, is in a container or package that does not bear a date or day, or is marked with a date or day that exceeds the time and temperature combination as required in this code. Employee discarded the wings.
3717-1-05.1(O)(2) / Using a handwashing sink - other uses prohibited.
Critical At the time of inspection, handwashing sink behind the bar was being used for purposes other than handwashing. Observed an accumulation of food debris and straws in the basin of the handwashing sink.
Remove all food and other debris from the basin of the handwashing sink behind the bar. A handwashing sink may not be used for purposes other than handwashing.
3717-1-05.3(C) / Backflow prevention.
Critical Repeat Observed a direct connection between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed (ice bin behind the bar and bar gun).
A direct connection may not exist between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed unless allowed by the Ohio building code. Provide a 1" air gap that eliminates the direct connection from the floor drain to the drainage lines of the ice bin and bar gun. Plumbing alterations should be made only by a licensed plumber.
3717-1-06.2(B) / Handwashing cleanser - availability.
Critical At the time of inspection, observed no supply of hand cleaning liquid, powder or bar soap at the handwashing sink behind the bar.
Each handwashing sink or group of two adjacent handwashing sinks shall be provided with a supply of hand cleaning liquid, powder, or bar soap.
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment.
Repeat At the time of inspection, observed an accumulation of food debris on the interior and exterior surfaces of the microwaves. Observed a black residue on the door gasket for the reach in freezer in the small storage room.
Clean the food debris and residues from this equipment and provide regular cleaning that maintains all food equipment clean to sight and touch.
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment.
(CORRECTED DURING INSPECTION) Exterior surfaces of the yeast container was dirty at the time of inspection.
A clean container was provided for yeast and the old container was discarded.
3717-1-06.4(D) / Cleaning ventilation systems, nuisance and discharge prohibition.
The ventilation system was not being properly cleaned. Observed an accumulation of dust and grease on vent covers of the hood over cooking surfaces.
Intake and exhaust air ducts shall be cleaned and filters changed so they are not a source of contamination. If vented to the outside, ventilation systems may not create a public health hazard or nuisance or unlawful discharge.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 20-March-2014
Comments |
---|
The handwashing sink in the women's restroom is properly supplied with hot and cold running water. Spray bottles filled with cleaning chemicals were clearly labeled at the time of inspection. Operation maintains temperature logs for refrigerated equipment. Walk-in cooler appeared well-organized at the time of inspection. Gaskets on the doors to the dough cooler are starting to show some wear and may need to be replaced soon. Pre-existing non-commercial food equipment in the facility is approved for use as long as it continues to function properly and is maintained clean. All newly purchased equipment shall be commercial grade. Contact the City of Kent Health Department for approval before placing any new equipment into use. |