3717-1-03.4(G) / Ready-to-eat, time/temperature controlled for safety food - date marking.
Critical Corrected During Inspection Observed chicken, taco meat, wings etc. without a date of expiration. Person-in-charge date marked the products. Refrigerated, ready-to-eat, TCS foods held refrigerated for more than 24 hours were not properly date marked.
To prevent foodborne illness, refrigerated, ready-to-eat, TCS food held at a temperature of 41°F or less for more than 24 hours shall be clearly marked at the time of preparation or the time the original container is opened to indicate the date or day, that is a maximum of seven days, by which the food shall be consumed, sold, or discarded. The day the food is prepared or opened is day one.
3717-1-04.1(KK) / Food equipment - certification and classification.
Observed a noncommercial microwave in the kitchen. Equipment is not approved by a recognized testing agency.
Food equipment that is acceptable for use in a FSO or RFE shall be approved by a recognized food equipment testing agency.
3717-1-06.4(B) / Cleaning - frequency and restrictions.
Repeat Observed build-up on the floor and walls by the fryer.
The physical facilities shall be cleaned as often as necessary to keep them clean, and cleaning shall be done during periods when the least amount of food is exposed.
[?] Facility Type: Commercial RFE < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 08-February-2017
Comments |
---|
Water was tested 10/20/16- No Coliform. |