3717-1-02.4(B) / Person in charge: demonstration of knowledge.
Critical Repeat The person in charge was unable to demonstrate proper knowledge of food safety (cooking, cooling and reheating) process.
To prevent or correct factors that may cause foodborne illness, based on the risks inherent to the food operation, during inspections and upon request, the person in charge shall demonstrate to the licensor the applicable food safety knowledge at the time of inspection.
3717-1-03.4(D) / Cooling - temperature and time control.
Critical Repeat TCS foods were not cooled using the proper time and temperature parameters. A cooling log was given to the manager.
To prevent the growth of pathogens, cooked TCS food shall be rapidly cooled: within two hours from 135°F to 70°F, and within a total of six hours from 135°F to 41°F or less; (2) TCS food shall be cooled within 4 hours to 41°F or less if prepared from ingredients at ambient temperature, such as reconstituted foods and canned tuna; (3) TCS food received in compliance with laws allowing a temperature above 41°F during shipment from the supplier, shall be cooled within 4 hours to 41°F or less; (4) Raw eggs shall be received at 45°F or less and immediately placed in refrigerated equipment that maintains an ambient air temperature of 45°F or less.
3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical Corrected During Inspection Observed chicken chunks at 110F. Person-in-charge voluntarly threw away the product. TCS foods were not being held at the proper temperature.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
3717-1-04.4(N)(3) / Manual and mechanical warewashing equipment, chemical sanitization (quaternary ammonium) - temp., pH, concentration, and hardness
Critical Corrected During Inspection Observed several buckets holding wiping clothes with the sanitizer solution weak. A quaternary ammonium sanitizing solution did not meet the minimum requirements for concentration.
To prevent pathogen growth, a quaternary ammonium sanitizing solution shall: (a) Have a minimum temperature of 75F,(b) Have a concentration as specified and as indicated by the manufacturer's use directions included in the labeling, (c) Be used only in water with 500 ppm (mg/l) hardness or less, or used in water having a hardness no greater than specified by the manufacturer's label.
3717-1-03.2(T) / Food preparation - preventing contamination from the premises
Observed food items (hamburgers, corn dogs, moz sticks, chicken etc.) not covered in the stand up freezer and cooler. Food is not protected from environmental sources of contamination during preparation.
During preparation, unpackaged food shall be protected from environmental sources of contamination.
3717-1-04.4(A)(1) / Equipment - good repair and proper adjustment.
Repeat Observed a tear in the stand up freezer and walk-in cooler gasket. Equipment and/or components are not maintained in good working order.
Equipment shall be maintained in a state of repair and condition that meets the requirements specified under rules 3717-1-04 and 3717-1-04.1 of this code.
3717-1-04.5(A)(2) / Cleanliness of food-contact surfaces of cooking equipment and pans.
Observed sticker residue on some clean dishes. Cooking equipment or pan surfaces are dirty.
To prevent contamination, the food-contact surfaces of cooking equipment and pans shall be kept clean.
3717-1-05.1(C)(1) / Handwashing sink - required water temperature
Observed a handwashing sink, closest to the drive-thru window, without water at the required temperature.
To ensure proper cleaning of hands, a handwashing sink shall be equipped to provide water at a temperature of at least 100° F (thirty-eight degrees Celsius) through a mixing valve or combination faucet.
3717-1-05.1(S)(2) / Plumbing system - maintained in good repair.
Observed the front hand sink draining very slow and the back handsink with a steady leak.
A plumbing system shall be properly maintained.
3717-1-06.2(F) / Disposable towels - waste receptacle.
Observed no waste receptacle at the handwashing sink(s).
A handwashing sink or group of handwashing sinks that is provided with disposable towels shall be provided with a waste receptacle.
[?] Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 22-June-2016
Comments |
---|
This firm is currently cooking, cooling and reheating the coney sauce everyday. They should be moved up to a license IV next year. |