3717-1-03.4(D) / Cooling - temperature and time control.
Critical TCS foods were not cooled using the proper time and temperature parameters.
To prevent the growth of pathogens, cooked TCS food shall be rapidly cooled: within two hours from 135°F to 70°F, and within a total of six hours from 70°F to 41°F or less; (2) TCS food shall be cooled within 4 hours to 41˚F or less if prepared from ingredients at ambient temperature, such as reconstituted foods and canned tuna; (3) TCS food received in compliance with laws allowing a temperature above 41˚F during shipment from the supplier, shall be cooled within 4 hours to 41˚F or less; (4) Raw eggs shall be received at 45°F or less and immediately placed in refrigerated equipment that maintains an ambient air temperature of 45°F or less. Correct By: 03-Nov-2014
3717-1-03.4(H)(1) / Ready-to-eat, time/temperature controlled for safety food - disposition.
Critical Corrected During Inspection Ready-to-eat, TCS food that had been date marked was not properly discarded when required. There was a package of swiss cheese and a package of american cheese in the large walkin cooler that were beyond the date of expiration.
To prevent illness, refrigerated, ready-to-eat TCS food that has been date marked in the facility shall be discarded if it: (a) exceeds the temperature or time specified in (G)(1) and (G)(2) of this rule, except the time the food is frozen; (b) is in a container or package that does not bear a date or day; or (c) is marked with a date or day that exceeds the time and temperature combination specified in (G)(1) and (G)(2) of this rule. Operator discard the cheese items.
[?] Facility Type: Non-Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 23-October-2014