3717-1-03.2(C) / Packaged and unpackaged food - preventing contamination by separation, packaging, and segregation
Critical Corrected During Inspection Observed food that was not properly protected from contamination by packaging. Items in the refrigerator and freezer are not covered for protection.
To prevent contamination, food shall be protected from cross contamination by separating raw animal foods during storage, preparation, holding, and display from cooked ready-to-eat food as described in this rule.
3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical Corrected During Inspection TCS foods were not being held at the proper temperature. Liquid eggs and shell eggs out of temperature.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
3717-1-04.5(A)(1) / Cleanliness of equipment food-contact surfaces and utensils.
Critical Equipment food-contact surfaces or utensils are dirty. Small prep cooler and hot holding.
To prevent contamination, equipment food-contact surfaces and utensils shall be clean to sight and touch.
3717-1-04.4(A)(1) / Equipment - good repair and proper adjustment.
Equipment and/or components are not maintained in good working order. Shell egg cooler door is broken and duct taped.
Equipment shall be maintained in a state of repair and condition that meets the requirements specified under rules 3717-1-04 and 3717-1-04.1 of this code.
3717-1-04.5(A)(2) / Cleanliness of food-contact surfaces of cooking equipment and pans.
Cooking equipment or pan surfaces are dirty.
To prevent contamination, the food-contact surfaces of cooking equipment and pans shall be kept clean.
3717-1-04.5(D) / Nonfood-contact surfaces - cleaning frequency.
Observed accumulation of soil residue on nonfood-contact surfaces of shelf under dish rack, dish rail, shelf at food pass thru, and dish trays.
Nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues.
3717-1-06.4(A) / Repairing.
The caulking is missing on the wall of the dish rinse area..
The physical facilities shall be maintained in good repair.
3717-1-06.4(B) / Cleaning - frequency and restrictions.
Observed a build-up of dirt and debris on wall throughout kitchen, grease area, pipes behind dishwasher, vent over dishwasher, and drain in the cooking area. A good all over cleaning is needed.
The physical facilities shall be cleaned as often as necessary to keep them clean, and cleaning shall be done during periods when the least amount of food is exposed.
[?] Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 11-September-2015
Comments |
---|
This firm is no longer reheating foods. March 1, 2016 they will be a level III. |