[?] A summary of the violations found during the inspection are listed below.

3717-1-04.1(D) / CIP equipment - cleanability.
Observed food build-up on the mixer. The facility's clean-in-place (CIP) equipment was not being properly cleaned and sanitized or monitored.
To prevent contamination: (1) CIP equipment shall meet the characteristics specified under paragraph (C) of this rule and shall be designed and constructed so that: (a) cleaning and sanitizing solutions circulate throughout a fixed system and contact all interior food-contact surfaces, and (b) the system is self-draining or capable of being completely drained of cleaning and sanitizing solutions; and (2) CIP equipment that is not designed to be disassembled for cleaning shall be designed with inspection access points to ensure that all interior food contact surfaces throughout the fixed system are being effectively cleaned.
3717-1-04.2(H)(2) / Temperature measuring devices - mechanical warewashing.
An irreversible registering temperature indicator (thermometer or labels) was not readily accessible in hot water mechanical warewashing operations.
A temperature measuring device is essential to monitor mechanical ware washing to ensure sanitization.
3717-1-06.4(A) / Repairing.
Observed damaged ceiling tiles in the storage room. The physical facilities are not being maintained in good repair.
The physical facilities shall be maintained in good repair.


Inspection Information


[?] Facility Type: Non-Commercial FSO < 25000 sq. ft.

[?] Inspection Type: Standard

Inspection Date: 15-September-2016