3717-1-07.1(A) / Poisonous or toxic materials: Storage: separation.
Critical Corrected During Inspection Observed chemicals stored with clean dishes. The person-in-charge moved the chemicals. Observed improper storage of poisonous or toxic materials.
To prevent contamination, poisonous or toxic materials shall be stored so they cannot contaminate food, equipment, utensils, linens, or single-service or single-use articles by: 1) Separating the poisonous materials by spacing or partitioning; and 2) Locating the poisonous or toxic materials in an area that is not above food, equipment, utensils, linens, single-service articles or single-use articles. .
3717-1-02.4(A)(2) / Person in charge: assignment of responsibility.
Facility did not have one employee with supervisory and management responsibility and the authority to direct and control food preparation and service with level two certification in food protection.
At least one employee that has supervisory and management responsibility and the authority to direct and control food preparation and service shall obtain the level two certification in food protection according to rule 3701-21-25 of the Administrative Code.
3717-1-04.1(A) / Equipment and utensils - durability and strength.
Observed a plastic dish that was cracked. Cracked dishes can no longer be washed, rinised, and sanitized properly.
Equipment and utensils shall be designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
3717-1-04.4(O) / Manual warewashing equipment - chemical sanitization using detergent-sanitizers
The facility did not have a detergent-sanitizer on hand.
If a detergent-sanitizer is used to sanitize where there is no distinct water rinse between the washing and sanitizing steps, the agent applied in the sanitizing step shall be the same detergent-sanitizer that is used in the washing step.
3717-1-04.8(E) / Equipment, utensils, linens, single-service articles, and single-use articles - storage.
Observed boxes of single use articles stored on the floor. Cleaned equipment and utensils, laundered linens, or single-service and single-use articles are not properly stored.
Cleaned equipment and utensils, laundered linens, single-service articles, and single-use articles shall be properly stored as described in this rule.
3717-1-04.8(E) / Equipment, utensils, linens, single-service articles, and single-use articles - storage.
Observed coffee filters that were not protected from contamination. Cleaned equipment and utensils, laundered linens, or single-service and single-use articles are not properly stored.
Cleaned equipment and utensils, laundered linens, single-service articles, and single-use articles shall be properly stored as described in this rule.
3717-1-06.2(I)(3) / Lighting - intensity (50)
Observed a light in the kitchen needing repaired. The light intensity in an area where an employee was working with food, utensils or equipment was less than fifty foot candles.
The light intensity shall be at least fifty foot candles (five hundred forty lux) at a surface where a food employee is working with food, utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor.
[?] Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 15-September-2017