3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical Corrected During Inspection McFrappe mix at 67 degrees F. PIC disposed of. TCS foods were not being held at the proper temperature.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
3717-1-03.4(G) / Ready-to-eat, time/temperature controlled for safety food - date marking.
Critical Corrected During Inspection Glazed onions in Delfield reach in had date mark of 9/20/15. PIC disposed of. Refrigerated, ready-to-eat, TCS foods held refrigerated for more than 24 hours were not properly date marked.
To prevent foodborne illness, refrigerated, ready-to-eat, TCS food held at a temperature of 41°F or less for more than 24 hours shall be clearly marked at the time of preparation or the time the original container is opened to indicate the date or day, that is a maximum of seven days, by which the food shall be consumed, sold, or discarded. The day the food is prepared or opened is day one.
3717-1-04.4(A)(1) / Equipment - good repair and proper adjustment.
Corrected During Inspection McFrappe machine was off, apparently the breaker had kicked it off. Water accumulation in the bottom. PIC had breaker turned back on and cleaned out. Have maintenance look at reason why breaker kicked off before putting back in operation. Equipment and/or components are not maintained in good working order.
Equipment shall be maintained in a state of repair and condition that meets the requirements specified under rules 3717-1-04 and 3717-1-04.1 of this code.
3717-1-04.4(A)(1) / Equipment - good repair and proper adjustment.
Eye wash station leaks at spigot and is loose. Equipment and/or components are not maintained in good working order.
Equipment shall be maintained in a state of repair and condition that meets the requirements specified under rules 3717-1-04 and 3717-1-04.1 of this code.
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment.
Ice machine had build up of debris on inside. Non-food contact surfaces of equipment are dirty.
Nonfood-contact surfaces of equipment shall be kept clean.
[?] Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 22-September-2015