3717-1-03.2(C) / Packaged and unpackaged food - preventing contamination by separation, packaging, and segregation
Critical Corrected During Inspection Observed raw foods stored above ready-to-eat foods in the walk-in cooler. Person-in-charge moved the raw foods to the bottom shelf. Observed food that was not properly protected from contamination by separation, packaging, and segregation.
To prevent contamination, food shall be protected from cross contamination by separating raw animal foods during storage, preparation, holding, and display from cooked ready-to-eat food as described in this rule.
3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical Corrected During Inspection Observed spring mix double panned on the salad make table at 43F. Person-in-charge remoeved the second pan. TCS foods were not being held at the proper temperature.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
3717-1-03.4(G) / Ready-to-eat, time/temperature controlled for safety food - date marking.
Critical Corrected During Inspection Observed the bacon cheddar tots without a date of expiration in the Avantco stand uop cooler. Person-in-charge date marked the product. Refrigerated, ready-to-eat, TCS foods held refrigerated for more than 24 hours were not properly date marked.
To prevent foodborne illness, refrigerated, ready-to-eat, TCS food held at a temperature of 41°F or less for more than 24 hours shall be clearly marked at the time of preparation or the time the original container is opened to indicate the date or day, that is a maximum of seven days, by which the food shall be consumed, sold, or discarded. The day the food is prepared or opened is day one.
3717-1-03.4(H)(1) / Ready-to-eat, time/temperature controlled for safety food - disposition.
Critical Observed spinach with a expiration date of 12/11/16 not discarded. Person-in-charge threw away the product. Ready-to-eat, TCS food that had been date marked was not properly discarded when required.
To prevent illness, refrigerated, ready-to-eat TCS food that has been date marked in the facility shall be discarded if it: (a) exceeds the temperature or time specified in (G)(1) of this rule, except the time the food is frozen; (b) is in a container or package that does not bear a date or day; or (c) is marked with a date or day that exceeds the time and temperature combination specified in (G)(1) of this rule.
3717-1-04.4(N)(3) / Manual and mechanical warewashing equipment, chemical sanitization (quaternary ammonium) - temp., pH, concentration, and hardness
Critical A quaternary ammonium sanitizing solution did not meet the minimum requirements for concentration in the sanitizer bucket in the kitchen and dinning area, Person-in-charge changed the water.
To prevent pathogen growth, a quaternary ammonium sanitizing solution shall: (a) Have a minimum temperature of 75F,(b) Have a concentration as specified and as indicated by the manufacturer's use directions included in the labeling, (c) Be used only in water with 500 ppm (mg/l) hardness or less, or used in water having a hardness no greater than specified by the manufacturer's label.
3717-1-03.2(K) / In-use utensils - between-use storage.
Observed utensil handles touching foods in the coolers under the grill and at the salad make table. In-use utensils are improperly stored.
During pauses in food preparation or dispensing, food preparation and dispensing utensils shall be stored as described in this rule.
3717-1-03.2(M) / Wiping cloths - use limitation.
Observed wet wiping cloths stored in a sanitizer solution that was not at the appropriate concentration. Observed improper use and/or maintenance of wiping cloths.
(1) Cloths that are in use for wiping food spills from tableware and carry-out container that occur as food is being served shall be maintained dry and used for no other purpose; (2) Cloths that are in use for wiping counters and other equipment surfaces shall be: (a) held between uses in a chemical sanitizer of the appropriate concentration; and (b) shall be laundered daily; (3) Cloths that are used with raw animal foods shall be kept separate from cloths used for other purposes; (4) Dry wiping cloths and the chemical sanitizing solution in which wet wiping cloths are held between uses shall be free of food debris and visible soil; (5) Containers of chemical sanitizing solutions specified in paragraph (M)(2)(a) of this rule in which wet wiping cloths are held between uses shall be stored off the floor and used in a manner that prevents contamination of food, equipment, utensils, linens, single-service articles, or single-use articles; (6) Single-use disposable sanitizer wipes shall be used in accordance with EPA-approved manufacturer's label use instructions.
3717-1-03.2(Q) / Food storage - preventing contamination from the premises.
Observed foods in the Avantco cooler and Victory freezer not properly covered to help prevent contamination. Observed improper storage of food items.
Food shall be protected from contamination by storing the food in a clean, dry location, where it is not exposed to splash, dust, or other contamination, and at least six inches above the floor.
3717-1-04.1(KK) / Food equipment - certification and classification.
Repeat Observed a non-commercial microwave by the salad make table. Equipment is not approved by a recognized testing agency.
Food equipment that is acceptable for use in a FSO or RFE shall be approved by a recognized food equipment testing agency.
3717-1-04.4(A)(1) / Equipment - good repair and proper adjustment.
Observed a torn gasket on the Avantco stand up cooler. Equipment and/or components are not maintained in good working order.
Equipment shall be maintained in a state of repair and condition that meets the requirements specified under rules 3717-1-04 and 3717-1-04.1 of this code.
3717-1-04.5(A)(2) / Cleanliness of food-contact surfaces of cooking equipment and pans.
Observed build-up inside the microwave. Cooking equipment or pan surfaces are dirty.
To prevent contamination, the food-contact surfaces of cooking equipment and pans shall be kept clean.
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment.
Observed food buildup in the coolers and freezers. Non-food contact surfaces of equipment are dirty.
Nonfood-contact surfaces of equipment shall be kept clean.
3717-1-04.8(E) / Equipment, utensils, linens, single-service articles, and single-use articles - storage.
Observed clean dishes/ plates/ bowls not properly inverted to help prevent contamination. Cleaned equipment and utensils, laundered linens, or single-service and single-use articles are not properly stored.
Cleaned equipment and utensils, laundered linens, single-service articles, and single-use articles shall be properly stored as described in this rule.
3717-1-06(A)(1) / Indoor areas - surface characteristics
Observed the floor by the 3-bay sink that is no longer easily cleanable.
Where FSO or RFE activities are conducted, materials for indoor floor, wall, and ceiling surfaces shall be smooth, durable, and easily cleanable; closely woven and easily cleanable carpet for carpeted areas; and nonabsorbent for areas subject to moisture.
3717-1-06.2(B) / Handwashing cleanser - availability.
The soap dispenser in the mens room was not properly working.
To ensure proper cleaning of hands, each handwashing sink or group of two adjacent handwashing sinks shall be provided with a supply of hand cleaning liquid, powder, or bar soap.
3717-1-06.3 (C)(2) / Employee accommodations - designated areas (lockers)
Observed employee coats being stored on food shelves.
Lockers or other suitable facilities shall be located in a designated room or area where contamination of food, equipment, linens, and single-service and single-use articles cannot occur.
3717-1-06.4(B) / Cleaning - frequency and restrictions.
Observed build-up on the floor under the equipment and dishwasher. Observed a build-up of dirt and debris.
The physical facilities shall be cleaned as often as necessary to keep them clean, and cleaning shall be done during periods when the least amount of food is exposed.
[?] Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 15-December-2016
Comments |
---|
This firm no longer reheats and will be moved to a risk level III March 1, 2017. |