3717-1-02.4(C)(14) / Person in charge: duties - ensure employees are informed in a verifiable manner of their responsibility to report their health information
Critical Person in charge did not ensure that employees are informed in a verifiable manner of their responsibility to report information about their health.
To prevent transmission of foodborne illness, the person in charge shall ensure that food and conditional employees are informed in a verifiable manner of their responsibility to report information about their health as it relates to diseases that are transmissible through food. Correct By: 28-May-2016
3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical CorrectedDuringInsp TCS foods were not being held at the proper temperature. The sausage in the prep cooler was 43 degrees.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
ADJUST THE COOLER DOWN TO MAINTAIN FOOD AT 41 DEGREES OR LESS. Correct By: 21-May-2016
3717-1-03.4(G) / Ready-to-eat, time/temperature controlled for safety food - date marking.
Critical CorrectedDuringInsp Refrigerated, ready-to-eat, TCS foods held refrigerated for more than 24 hours were not properly date marked. The salami and cooked vegetables were not date marked in the reach in cooler.
To prevent foodborne illness, refrigerated, ready-to-eat, TCS food held at a temperature of 41°F or less for more than 24 hours shall be clearly marked at the time of preparation or the time the original container is opened to indicate the date or day, that is a maximum of seven days, by which the food shall be consumed, sold, or discarded. The day the food is prepared or opened is day one.
DATE MARK COOKED VEGETABLES AND READY TO EAT MEAT. Correct By: 21-May-2016
3717-1-03.5(E) / Consumer advisory.
Critical The consumer is not properly advised of the risk of consuming raw or undercooked animal foods.
The reminder shall include asterisking the animal-derived foods requiring disclosure to a footnote that states: (1) Regarding the safety of these items, written information is available upon request; (2) Consuming raw or undercooked meats, poultry seafood, shellfish, or eggs may increase your risk of foodborne illness; or (3) Consuming raw or undercooked meats, poultry seafood, shellfish, or eggs may increase your risk of foodborne illness, especially if you have certain medical conditions. Correct By: 28-May-2016
3717-1-04.4(N)(1) / Manual and mechanical warewashing equipment, using chemical sanitization (chlorine) - temp., pH, concentration, and hardness
Critical The concentration and/or temperature of a chlorine sanitizing solution did not meet the minimum requirements specified in the code. The dishwasher was not dispensing sanitizer.
To prevent pathogen growth, a chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as specified in the code.
REPAIR DISHWASHER SANITIZER DISPENSER. UNTIL FIXED HAND SANITIZE DISHES. Correct By: 25-May-2016
3717-1-05.1(D) / Backflow prevention - air gap.
Critical Repeat Observed the air gap between a plumbing fixture and a piece of equipment that was not sufficient to prevent back siphonage of contaminated water. The ice machine did not have an air gap on one drain.
To prevent contamination, an air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment, or nonfood equipment shall be at least twice the diameter of the water supply inlet and may not be less than one inch (25 millimeters).
PROVIDE AN AIR GAP ON BOTH DRAINS FROM THE ICE MACHINE. Correct By: 21-May-2016
3717-1-06.1(D)(1) / Floor carpeting - restrictions and installation.
Observed carpeting installed in unapproved areas. Observed rug in from of dishwasher.
Carpeting or similar material shall not be installed in food preparation areas, walk-in refrigerators, warewashing areas, toilet rooms, refuse storage rooms, or other areas where the floor is subject to moisture, flushing or spraying.
REMOVE RUG FROM KITCHEN. RUBBER MATS ARE ACCEPTABLE. Correct By: 28-May-2016
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 21-May-2016
Comments |
---|
Cut roasts into 3-6 lbs parts after coking and to cool. The wording for a consumer advisory is listed in the violations section. This is not a violation, but the wording for the menu is provided. The pad for the dumpster is planned for installation. The pad for the grill is planned for installation |