3717-1-05.1(D) / Backflow prevention - air gap.
Critical Observed the air gap between a plumbing fixture and a piece of equipment that was not sufficient to prevent back siphonage of contaminated water. One drain from the ice machine is below the rim of the floor drain.
To prevent contamination, an air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment, or nonfood equipment shall be at least twice the diameter of the water supply inlet and may not be less than one inch (25 millimeters).
RAISE THE DRAIN PIPE FROM THE ICE MACHINE SO THE END IS ABOVE THE TOP OF THE FLOOR DRAIN. Correct By: 23-Nov-2015
3717-1-05.1(O)(2) / Using a handwashing sink - other uses prohibited.
Critical CorrectedDuringInsp Handwashing sink is being used for purposes other than handwashing. The bar hand sink was used to drain fruit and ice.
To prevent contamination, a handwashing sink may not be used for purposes other than handwashing.
DRAIN FRUIT IN THE 3 COMPARTMENT SINK IN STRAINER. Correct By: 21-Nov-2015
3717-1-05.4(B) / Outdoor storage surface.
Repeat Outdoor refuse storage surface is not properly constructed, and sloped to drain. The asphalt under the dumpster is crumbling.
An outdoor storage surface for refuse, recyclables, or returnables shall be constructed of nonabsorbent material and shall be smooth, durable, and sloped to drain.
RESURFACE THE ASPHALT UNDER THE DUMPSTER.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 21-November-2015
Comments |
---|
The bottom shelf of the table next to the dishwasher is becoming rusty. If necessary paint the shelf. Remember to keep wiping cloths in a sanitizer bucket between uses, not hung over the rink of the sink. The surface of the ground where you do grilling next summer must be concrete or asphalt. These items were corrected since the 3-28-15 inspection: -Employee drinks are not uncovered in the kitchen -a thin probe thermometer is available and working -water is not pooling on the bottom of the reach in cooler -a hand wash sign is posted at the bar sink -the dumpster lid is closed. |