3717-1-03.2(C) / Packaged and unpackaged food - preventing contamination by separation, packaging, and segregation
Critical CorrectedDuringInsp Observed food that was not properly protected from contamination by separation, packaging, and segregation.OBSERVED RAW BACON & SAUSAGE STORED OVER TOP OF READY TO EAT BOLOGNA & HOT DOGS.
To prevent contamination, food shall be protected from cross contamination by separating raw animal foods during storage, preparation, holding, and display from cooked ready-to-eat food as described in this rule. Correct By: 07-Mar-2016
3717-1-04.1(Y) / Temperature measuring devices.
CorrectedDuringInsp Cold or hot holding equipment did not contain a thermometer, or the thermometer was not correctly placed. OBSERVED THE BEVERAGE AIR MILK COOLER IN THE BACK ROOM TO NOT HAVE A TEMP MEASURING DEVICE.
A properly designed temperature measuring device as specified in this rule shall be located in the warmest part of a cooling unit or the coolest part of a food warming unit. PLACE A TEMPERATURE MEASURING DEVICE IN THE BEV AIR MILK COOLER. Correct By: 07-Mar-2016
Facility Type: Commercial RFE < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 07-March-2016
Comments |
---|
REVIEWED INSPECTION WITH JACKIE HIVELY, PERSON IN CHARGE. DISCUSSED CHANGES IN RULES. |