3717-1-04.4(A)(2) / Equipment components kept intact, tight, and adjusted
Equipment components are not intact, tight or properly adjusted. OBSERVED: Two make table units were not being used because the temperature does not maintain 41 degrees or below. PIC stated that both units need compressor work, and repair orders have been made. ice is maintained under sliced tomatoes/ lettuce and the masterbilt cooler is used.
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment.
Non-food contact surfaces of equipment are unclean. OBSERVED: the toastmaster grill/oven in the back to have a build up of grease debris. Clean the exterior more frequently.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard/Critical Control Point
Inspection Date: 17-January-2021
Comments |
---|
All Temps acceptable at the time of inspection No critical violations observed during inspection. Observed handwashing by employees during inspection. |
IV - P - Demonstration of Knowledge: The person in charge is Certified in Food Protection. II - P - Good Hygienic Practices: Food employee working with exposed foods, clean equipment, utensils, linens or unwrapped single-service or single use articles was not experiencing discharge from eyes, nose, or mouth. II - P - Good Hygienic Practices: Food employee was demonstrating good hygiene practices. IV - P - Demonstration of Knowledge:The operation is in compliance with Chapter 3717-1 of the Administrative Code. VII - P - Protection from Contamination: Observed raw animal foods separated by type during storage, preparation, holding, and display. III - P - Preventing Contamination by Hands: Observed food employee washing hands when required. III - P - Preventing Contamination by Hands: Observed food employee changing gloves when required. VII - P - Protection from Contamination: Foods are protected from physical and environmental contamination during storage, preparation, holding and display. VI - P - TCS Food: Observed ready to eat TCS foods being properly date marked, and discarded when required. VI - P - TCS Food: Observed hot foods being held at 135°F or above; cold foods being held at 41°F or below. Food Process Reviewed: VII - P - Protection from Contamination: Observed employee properly cleaning and sanitizing food contact surfaces. III - P - Preventing Contamination by Hands: Observed food employee washing hands prior to donning single use gloves. II - P - Good Hygienic Practices: Food employee(s) were eating, drinking or using tobacco in designated area. X - P - Chemical: Sulfites are not applied to fresh fruits or vegetables intended for raw consumption. I - P - Employee Health: The person in charge reports any known reportable foodborne diseases to the licensor as required. III - P - Preventing Contamination by Hands: Food employees were not contacting exposed ready-to-eat foods with bare hands. I - P - Employee Health: The person in charge properly applies restrictions and exclusions for ill employees. I - P - Employee Health: The operation had an employee health policy on file. X - P - Chemical: No unapproved food or color additives are used. III - P - Preventing Contamination by Hands: Hand washing facilities are properly supplied. X - P - Chemical: Toxic materials are properly identified and stored. |